4.5. Other Output Signals
4.5.1. Servo alarm output
The following diagram shows the right way to connect Alarm Output.
Ex24 V I/O power supply is required, since there is no +24 V power supply available inside servo
drive.
The signal outputs when servodrive is detected abnormal.
Normally, the external circuit consists of /ALM should be able to switch off power of servo drive.
When “servo alarm (ALM)” happens, always remove alarm reasons first, and then turn the input signal
"/ALM-RST" to ON position to reset alarm status.
Normally, the external circuit can switch off power supply of servo drive when alarm occurs. When servo
drive is re-switched on, it removes alarm automatically, so normally alarm reset signal is not required to
be connected.
In addition, alarm reset are enabled with panel operator.
Note:
When alarm occurs, always remove alarm reasons before resetting alarms.
Output
ALM+ 1CN- 7
Servo alarm output
Output
ALM- 1CN- 8
Servo alarm output uses grounding signal
Signal
Status
Output level
Comments
ALM
ON
1CN-7:“L” level
Normal state
OFF
1CN-8:“H” level
Alarm state
Input /ALM-RST 1CN- 39
alarm reset input
Signal
Status
Output level
Comments
/ALM-RST
ON
1CN-39:“L” level
Reset servo alarm
OFF
1CN-39:“H” level
Do not reset servo alarm
Summary of Contents for BCSD-08AMA-01
Page 1: ...SYSTEM BCSD User manual Ref 1809...
Page 3: ...FAGOR AUTOMATION S COOP Brushless AC Servo Drives BCSD series Ref 1809...
Page 29: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 29 116 BCSD 30D 50D unit mm...
Page 38: ...BCSD 38 116 Digital Brushless AC Servo Drive system Ref 1809 Three phase 400V BCSD 10D 50D...
Page 114: ...BCSD 114 116 Digital Brushless AC Servo Drive system Ref 1809...
Page 115: ...Digital Brushless AC Servo Drive system Ref 1809 BCSD 115 116 User notes...
Page 116: ...BCSD 116 116 Digital Brushless AC Servo Drive system Ref 1809 User notes...
Page 117: ......