ENGLISH
INSTALLATION MANUAL ADVANCE PLUS
26
GAS CONNECTION
Warning:
The gas installation may only be connected by an authorised local gas
technician.
It is essential to ensure that the gas supply pipes and the connection pipes for
the corresponding measurement systems are the correct diameter.
Check that the gas supply is correctly sealed.
MAXIMAL TERMAL LOAD
Type of gas
Required
Fluidity
pressure
(mbar)
APG-061
APG-101
APG -201
APG -102
APG -202
Natural gas H G-20 (m³/h)
20
1,270
1,905
3,809
3,704
6,878
Butane gas G-30 (kg/h)
29
0,998
1,498
2,995
2,912
5,408
Propane gas G-31(kg/h)
37
0,984
1,476
2,951
2,869
5,329
The air required for combustion of 2m3 / h per kW of power.
Remarks:
Observe the regulations issued by the local gas company.
Observe the regulations for the installation.
Check that the gas indicated in the section is identical to that supplied.
A pipe of at least Ø 12 x 10 mm should be used for the gas connection to the
appliance, together with a ¾” nut to connect to the oven (Fig. 9 and Fig. 10)
Gas shut-off valve in front of each appliance.
Summary of Contents for Advance Plus APG-061
Page 1: ...1 MANUAL DE INSTALACION MODELOS APG 061 APG 101 APG 201 APG 102 APG 202 12044974...
Page 18: ...ESPA OL MANUAL DE INSTALACION ADVANCE PLUS 18 INSTRUCCIONES DE DESPALETIZACION...
Page 36: ...ENGLISH INSTALLATION MANUAL ADVANCE PLUS 36 REMOVAL FROM PALLETS INSTRUCTIONS...
Page 54: ...DEUTSCH INSTALLATIONSHANDBUCH ADVANCE PLUS 54 PALETTE ANWEISUNGEN ZUM ENTFERNEN...
Page 72: ...FRAN AIS MANUEL D INSTALLATION ADVANCE PLUS 72 LES INSTRUCTIONS DE DEMONTAGE DE PALETTES...
Page 90: ...ITALIANO MANUALE DI INSTALLAZIONE ADVANCE PLUS 90 ISTRUZIONI DI RIMOZIONE DI IL PALLET...