15
TRANSFORMATION FROM NATURAL GAS TO LPG AND FROM LPG TO NATURAL GAS
1.
Turn off gas and electricity of the cooktop. If your cooktop is hot, wait
for cooling down.
2.
For injector change, use a screwdriver whose edge is as the Figure 4.
3.
As seen in Figure 5, demount burner lid and burner of the cooktop
and ensure visibility of injector.
4.
Remove injector by turning as shown in Figure 6 with screwdriver and
replace it with a new one.
5.
After that, detach control switches of the cooktop. Make setting by
turning the screw in the middle of gas cocks with a small screwdriver
in the manner shown in the following picture. To adjust flow rate screw,
use a screwdriver having suitable dimension. For LPG, turn the screw
clockwise. For natural gas, turn the screw one time counter clockwise.
At low position, length of normal flame should be 6-7 mm. For the last
control, check out whether flame is open or closed.
Setting of your appliance may differ according to the type of gas cock
used.
GAS BREAKING SAFETY APPLİANCE (FFD)
Against putting out to be taken place as a
result of liquid overflow at upper burners, safety
appliance steps in and cut gas immediately.
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9
FFD
GB