10
3.
Connect your appliance to gas cock from the shortest way and in a
manner to prevent any leakage. For safety, the hose used should be max-
imum 125 cm and minimum 40 cm.
4.
While making gas leakage control; never use lighter, match, glowing
cigarette or similar inflammable matter.
5.
Apply soap bubble on connection point. If any leak/leakage exists,
foaming will occur on soaped region.
6.
If the cooktop is to be mounted on a cabinet or openable drawer, a
heat protection panel having 15 mm minimum opening should be mount-
ed under the cooktop.
SETTING GAS COOKTOPS AS PER GAS TYPE
Gas type (LPG or natural gas) that your appliance is manufactured for
is stated in the label found behind the product and that show technical
features. If gas setting of your appliance is not the same as gas setting
of your network, it should be adjusted by making change by an expert
person. In the following table, injector, gas flow and power values of ap-
pliance is given according to gas type.
LPG (Cylinder)
G30-30 mbar
Natural gas
G20-20 mbar
Large
Burner
Injector
mm
0.85
mm
1.15
Gas Flow
g/h
198
g/h
0.263
Power
kW
2.75
kW
2.75
Wok
Burner
Injector
mm
0.96
mm
1.30
Gas Flow
g/h
259.20
g/h
0.300
Power
kW
3.60
kW
3.35
Medium
Burner
Injector
mm
0.65
mm
0.97
Gas Flow
g/h
115.20
g/h
0.165
Power
kW
1.60
kW
1.70
Small
Burner
Injector
mm
0.50
mm
0.72
Gas Flow
g/h
64.80
g/h
0.086
Power
kW
0.90
kW
0.90
GB