![fafnir VISY-Density LPG Technical Documentation Manual Download Page 34](http://html1.mh-extra.com/html/fafnir/visy-density-lpg/visy-density-lpg_technical-documentation-manual_537390034.webp)
Page 31/55
Installation
5.4
Installation offset
Figure 20: Installation offset
The VISY-Stick sensors are installed vertically in the tanks as close as possible to the central
vertical axis. Afterwards, it will be necessary to configure the respective positions of the sensors
in VISY-Command using the installation offset. The offset is composed of the distance (b) of the
probe tube (see Figure 20) to the tank bottom plus the safety distance (see Figure 14). The in-
stallation offset is transmitted to VISY-Command during configuration of the individual
measuring points using the VISY-Setup software application.
Figure 20 shows the probe distance (b) from the lowest point of the tank bottom for cylindrical
tanks according to DIN 6608, 6616, 6617, and 6624 depending on probe distance (a) from the
central vertical axis when the probe is in contact with the tank wall.
Tank Durchmesser
0
10
20
30
40
50
60
70
80
90
100
110
0
50
100
150
200
250
300
350
400
Sondenabstand (a) zur zentralen vertikalen Achse [mm]
Sonde
na
bs
ta
nd (
b)
z
um
T
ank
bode
n [
m
m
]
1600 mm
2000 mm
2500 mm
2900 mm
Probe distance (a) from central vertical axis [mm]
Pr
obe d
ist
an
ce (
b)
fr
om
ta
nk
bo
tto
m
[m
m
]
Tank diameter
a
b