![fafnir VISY-Density LPG Technical Documentation Manual Download Page 15](http://html1.mh-extra.com/html/fafnir/visy-density-lpg/visy-density-lpg_technical-documentation-manual_537390015.webp)
Level Sensors
Page 12/55
3.3.6
VISY-Stick Flex / Flex Biodiesel / Flex E15
The level sensor VISY-Stick Flex is a VISY-Stick with flexible probe tube. The magnetic base at
the lower end of the probe tube keeps the sensor attached to the tank bottom after installa-
tion. The sensor installation is possible only with screw-in unit.
Figure 7: VISY-Stick Flex
Pr
obe l
eng
th
appr
. 1
23
∅
47.2
∅
43
120
Ad
ju
st
in
g r
an
ge
M12 coupling
1 brown +
2 white A
3 blue
–
4 black B
Equipotential bonding connection
Probe head
Screw-in unit R1½, SW 55, stainless steel
Probe tube
∅
12, stainless steel
(500 mm)
Corrugated hose
∅
12, stainless steel
Probe tube
∅
12, stainless steel
(500 mm)
Product float,
∅
43 x 43
Water float,
∅
43
Weight, stainless steel
Magnetic base
Dimensions in mm
∅