3. Electrical Installation Rules
Prior to installation, make sure there is a circuit breaker installed with a distance between the contacts that allows for
complete disconnection when there is a category III overload and that provides protection against current leakage equal to
30 mA. The circuit breaker must be installed on the power supply in compliance with installation rules.
If the power supply is not working properly, the machine can cause transitory voltage drops.
The electrical safety of this machine is only ensured when it is correctly connected to an efficient earthing system in compliance with the electrical
safety laws in force. This fundamental safety requirement must be verified. If in doubt, request that a qualified electrician inspect the system. The
manufacturer cannot be held responsible for any damage caused by the lack of an earthing system on the electrical supply.
Do not use adaptors, multiple plugs, and/or extension cords.
Check that the type of connection and voltage correspond with the information on the nameplate: see
illustrations chapter figure 1
.