English
22 EN
11. Programming
Coffee Boiler -
this parameter includes
the entries for setting the temperature
of the coffee boilers, values that can
be set are 60 to 110°C (140 to 230°F)
in steps of 0.5°C. In this menu there is
also the possibility of programming an
offset
of temperature for the boilers
which can be modified in a range of
+/- 2°C.
Softener Reg.
-
includes the
parameters for the resin regeneration:
resin litres (between 0.1l and 25l),
hardness (between 0 and 45 °F). The
decreasing resin efficiency level is
also indicated. Once the softener
regeneration has been performed,
press the icon
to cancel the
message.
Change W. Filter
-
On reaching the litre
level set on the display a message is
displayed which prompts replacement
of the filter.
The efficiency percentage is displayed
(Softener/Filter) decreasing from
100% to 0%.
Once the filter has been replaced, push
the
icon to cancel the message.
Maintenance
-
includes 4 submenus
for setting maintenance parameters:
- Max cycles -
the number of cycles
set.
- Max days -
the number of days set.
- No. cycles/days -
this is the
number of cycles and days until next
maintenance.
- Maintenance -
YES/NO.
Enables (YES) or does not enable
countdown of the cycles and days until
the next maintenance activity.
O n c e
the maintenance has been performed,
press the icon
to cancel the
message.
BDS
-
see section “BDS Activation” in
the following pages.
Flush
-
Not active.
Low power
- YES/NO
Drying
- Not active.
Screensaver
-
Possibility of program-
ming the screensaver display time
(from 30" to 20')
Standard data -
allows loading of
standard data or reconfiguration of the
machine. In both cases the machine is
automatically restarted.
Password-
allows change of the code
for accessing technical programming.
Summary of Contents for E71 E
Page 2: ...I 1 14 15 15 12 3 16 5 2 2 15 Tsn 6 6 7 PRG 11 4 3 4 3 4 13 10 9 8 12 17 19 18...
Page 52: ...English 47 EN 14 Cup Warmer 1 2 3...
Page 53: ...English 48 EN 15 Stainless steel front panel 1 2...
Page 55: ...English 50 EN 17 Draining the boiler water...
Page 57: ...English 52 EN 20 Coffee boiler 0 6 mm...
Page 58: ...English 53 EN 21 display panel...
Page 59: ...English 54 EN 22 Junction Box 23 Safety thermostat 1 4 3 2 1 4 2 3...
Page 61: ...English 56 EN FUSE BATTERY Battery Fuse CR 2032 3V CR 2032 3V...