background image

2

Oil-hydraulic KIT operator for swinging gates

up to 2,3 m per leaf

HINDI 880 SPRINT

English

GENERAL WARNINGS FOR PEOPLE SAFETY

THANK YOU

Thank you for purchasing a Fadini product. 
Please read these instructions carefully before using this 
appliance. The instructions contain important information 
which will help you get the best out of the appliance and 
ensure safe and proper installation, use and maintenance. Keep 
this manual in a convenient place so that you can always refer 
to it for the safe and proper use of the appliance.

INTRODUCTION 

This operator is designed for a specific scope of applications as 
indicated in this manual, including safety, control and signaling 
accessories as minimum required with Fadini equipment. 

 Any 

applications not explicitly included in this manual may cause 
operation problems or damages to properties and people. 

 

Meccanica Fadini S.r.l. is not liable for damages caused by the 
incorrect use of the equipment, or for applications not included 
in this manual or for malfunctioning resulting from the use of 
materials or accessories not recommended by the 
manufacturer. 

 The manufacturer reserves the right to make 

changes to its products without prior notice. 

 All that is not 

explicitly indicated in this manual is to be considered not 
allowed.

BEFORE INSTALLATION

Before commencing operator installation assess the suitability 
of the access, its general condition and the structure. 

 Make 

sure that there is no risk of impact, crushing, shearing, 
conveying, cutting, entangling and lifting situations, which 
may prejudice people safety. 

 Do not install near any source of 

heat and avoid contacts with flammable substances. 

 Keep all 

the accessories able to turn on the operator (transmitters, 
proximity readers, key-switches, etc) out of the reach of the 
children. 

 Transit through the access only with stationary 

operator. 

 Do not allow children and/or people to stand in the 

proximity of a working operator. 

 To ensure safety in the 

whole movement area of a gate it is advisable to install 
photocells, sensitive edges, magnetic loops and detectors. 

 

Use yellow-black strips or proper signals to identify dangerous 
spots. 

 Before cleaning and maintenance operations, 

disconnect the appliance from the mains by switching off the 
master switch. 

 If removing the actuator, do not cut the 

electric wires, but disconnect them from the terminal box by 
loosening the screws inside the junction box.

INSTALLATION

All installation operations must be performed by a qualified 
technician, in observance of the Machinery Directive 
2006/42/CE and safety regulations EN 12453 - EN 12445. 

Verify the presence of a thermal-magnetic circuit breaker 0,03 
A - 230 V - 50 Hz upstream the installation. 

 Use appropriate 

objects to test the correct functionality of the safety 
accessories, such as photocells, sensitive edges, etc. 

 Carry out 

a risk analysis by means of appropriate instruments measuring 
the crushing and impact force of the main opening and closing 
edge in compliance with EN 12445. 

 Identify the appropriate 

solution necessary to eliminate and reduce such risks. 

 In case where the gate to automate is equipped with a 

pedestrian entrance, it is appropriate to prepare the system in 
such a way to prohibit the operation of the engine when the 
pedestrian entrance is used. 

 Apply safety nameplates with 

CE marking on the gate warning about the presence of an 
automated installation. 

 The installer must inform and 

instruct the end user about the proper use of the system by 
releasing him a technical dossier, including: layout and 
components of the installation, risk analysis, verification of 
safety accessories, verification of impact forces and reporting 
of residual risks.

INFORMATION FOR END-USERS

The end-user is required to read carefully and to receive 
information concerning only the operation of the installation 
so that he becomes himself responsible for the correct use of it. 

 The end-user shall establish a written maintenance contract 

with the installer/maintenance technician (on -call). 

 Any 

maintenance operation must be done by qualified technicians. 

 Keep these instructions carefully.

WARNINGS FOR THE CORRECT OPERATION OF THE 
INSTALLATION

 

For optimum performance of system over time according to 
safety regulations, it is necessary to perform proper 
maintenance and monitoring of the entire installation: the 
automation, the electronic equipment and the cables 
connected to these. 

 The entire installation must be carried 

out by qualified technical personnel, filling in the Maintenance 
Manual indicated in the Safety Regulation Book (to be 
requested or downloaded from the site 
www.fadini.net/supporto/downloads). 

 Operator: 

maintenance inspection at least every 6 months, while for the 
electronic equipment and safety systems an inspection at least 
once every month is required. 

 The manufacturer, Meccanica 

Fadini S.r.l., is not responsible for non-observance of good 
installation practice and incorrect maintenance of the 
installation.

DISPOSAL OF MATERIALS

Dispose properly of the packaging materials such as 
cardboard, nylon, polystyrene etc. through specializing 
companies (after verification of the regulations in force at the 
place of installation in the field of waste disposal). Disposal of 
electrical and electronic materials: to remove and dispose 
through specializing companies, as per Directive 2012/19/UE. 
Disposal of substances hazardous for the environment is 
prohibited.

Meccanica Fadini S.r.l.

Director in charge

CE DECLARATION OF CONFORMITY of the manufacturer:

Meccanica Fadini S.r.l. (Via Mantova, 177/A - 37053 Cerea - VR - Italy) declares under own responsibility that:

Hindi 880 Sprint

 complies with the 2006/42/CE Machinery Directive, and also that it is sold to be installed in an “automatic 

system”, along with original accessories and components as indicated by the manufacturing company. An automatic gate 
operator is, by law, a “machinery” and therefore the installer must fit the equipment with all of the applicable safety norms. 
The installer is also required to issue the installer’s Declaration of Conformity. The manufacturer is not liable for possible 
incorrect use of the product. The product complies with the following specific norms: analysis of the risks and subsequent 
action to cure them as per EN 12445 and EN 12453, Low Voltage Directive 2014/35/UE, Electromagnetic Compatibility 
2014/30/UE. In order to certify the product, the manufacturer declares under own responsibility the compliance with the 
EN 13241-1 PRODUCT NORMS.

istr_hindi880sprint_GB.ai   2   21/04/2023   10:02:49

Summary of Contents for HINDI 880 SPRINT

Page 1: ...EN 13241 EN 12453 EN 12445 HINDI 880 SPRINT Oil hydraulic KIT operator for swinging gates up to 2 3 m per leaf GB Instructions manual pages 1 8...

Page 2: ...estrian entrance it is appropriate to prepare the system in such a way to prohibit the operation of the engine when the pedestrian entrance is used Apply safety nameplates with CE marking on the gate...

Page 3: ...r s care to properly lay the pipes and tubes required for the connections 1 Flasher in the kit 2 Controller item 7047L with plug in receiver in the kit 3 230 V 50 Hz 0 03 A magneto thermal differentia...

Page 4: ...lease system is under the valve Use the release spanner as indicated in the picture Oil hydraulic KIT operator for swinging gates up to 2 3 m per leaf HINDI 880 SPRINT 4 1 2 3 4 Pic 3 Pic 4 Pic 5 2 tu...

Page 5: ...thrust power in opening and closing unscrew or tighten the adjusting screws under the protection cover Pic 7 Red screw controls thrust power in closing cycle Green screw controls thrust power in openi...

Page 6: ...on stroke 235 mm Piston diameter 45 mm Shaft diameter 16 mm Working temperature 25 C 80 C A Weight complete with accessories 9 5 kg Max gate weight per leaf 400 kg Max gate width per leaf 2 3 m Protec...

Page 7: ...ad barrier Operator model Dimensions per gate leaf Weight per gate leaf Installation date Quantity of models installed Maintainer Date NOTE WELL this document must record any ordinary and extraordinar...

Page 8: ...e at the place of installation in the field of waste disposal Disposal of electrical and electronic materials to remove and dispose through specializing companies as per Directive 2012 19 UE Disposal...

Reviews: