English
FIXING GEOMETRY FOR THE GATE TO OPEN INWARDS
90°
FIXING PREPARATION
First weld the front bracket and rear plate to patch plates (not supplied with the equipment), perfectly leveled (Pic. 5).
FIRST OPERATIONS TO PULL THE SHAFT OUT
Before fixing the operator to the gate and gate post, pull the shaft out (Pic. 3). Release by the spanner provided with the equipment (version with
hydraulic locking valve); with the non locking (reversible) version, this operation is not required: the release system is under the valve. (Use the
release spanner as indicated in the picture).
Oil-hydraulic KIT operator for swinging gates
up to 2,3 m per leaf
HINDI 880 SPRINT
4
1
2
3
4
Pic. 3
Pic. 4
Pic. 5
2 turns max
Pull out to the end
of the permitted stroke
Push back
a few millimeters
Tighten
hard
3-5 mm
A = 110 mm
B = 110 mm
Plate
for post fixing
Gate stop
in open position
Bracket
for gate fixing
Gate stop
in closed position
This measure depends
on distance B (Pic. 4)
Metal patch plate (optional).
With heavy gates it is recommended that the plates be adequate to the
gate features. In case of light gates, made of either aluminium panels or
wood, use through screws and counter-plates.
istr_hindi880sprint_GB.ai 4 21/04/2023 10:02:50