www.factorelectronics.com
V-66 INSTALLATION INSTRUCTIONS USING THE 12V TRIGGERS
INSTALLATION:
Using the V-66 12VDC Trigger Inputs and Outputs
The V-66 provides 6 x 12VDC trigger outputs which correspond to the 6 x V-66 zones. When a zone is powered ON by pressing and
holding the SELECT button on the V-66-KP (keypad) for 3 seconds the corresponding zone sends 12VDC to the trigger output jack.
When the zone is powered OFF the routed 12VDC signal is disengaged. Triggers can be used to automatically power peripheral
equipment ON/OFF with the V-66 zones. The V-66 also provides a master control 12VDC trigger output which sends 12VDC to the
CONTROL OUT jack when any zone is powered ON. The 12VDC CONTROL OUT signal is disengaged when all zones are powered OFF.
V-66 Trigger outputs:
ZONE 1-6:
Zone ON 12VDC applied to output jack Zone OFF 12VDC disengaged
CONTROL:
Any zone ON 12VDC applied to output jack Zone OFF 12VDC disengaged
V-66 Trigger Inputs:
PA- IN
- Insert 12VDC and Input 1 takes priority over all other inputs and broadcasts to all 6 zones.
MUTE - IN
- Insert 12VDC and all zones will be muted. (no sound)
WIRING:
3.5mm Mono Plug (Tip + / Sleeve -)
+ -
Motorized Projection Screen
12VDC Trigger In
External Amplifier Control
12VDC Trigger In