![Facom B12.SECU Original Instructions Manual Download Page 5](http://html1.mh-extra.com/html/facom/b12-secu/b12-secu_original-instructions-manual_3150550005.webp)
1/ WARNING:
• The BOOSTER should always be used by skilled personnel.
• Warnings and instructions of the vehicle maker must be applied at all times.
• Wear protection goggles and equipment specified by regulations.
• Whenever left unused, the BOOSTER must be in charge.
• Always wind and store the cables properly to avoid any risk of contact between the clamps.
• Never produce short-circuits.
• Never use a 12 Volt BOOSTER on a 24 Volt vehicle.
• After-sales interventions must be performed only by FACOM After-sales.
2/ SPECIFICATIONS :
B12.SECU
Usage voltage
12V
Max Peak current
3500A
Cranking current
1300A
TCFC current*
780A
Battery capacity
1 X 22 Ah
Battery type
AGM
Battery reference
B12.SECU-BAT
Cable Ø
25mm²
Cable type
Double insulation copper
Cable length
155 cm
Clips
850 A Bronze
Weight
11.2KG
Fuse type
MEGA
Power fuse
300A
Fuse reference
BF300A
Voltage selection
No
Safeties
Fuse
Charger type
Automatic 2A
INPUT charger
120-240 V 50/60 hz
OUTPUT charger
DC 12V 2A
EU charger reference
B12-CH2
UK charger reference
Not available
EN
Summary of Contents for B12.SECU
Page 23: ...NOTA...