1. 

Install the grease filters using two hands by first pulling and 

turning the knob to the left so that the locking lever does not 

protrude from the filter 

(as in FIGURE 12)

.  Insert the opposite 

end of the filter into the retaining channel.  Insert the knob end 

next, then turn knob to the right to lock the filter into place.

Rangehood Control Panel

The control panel is located on the front edge of the rangehood 

canopy.  The position and function of each control button are 

indicated in 

FIGURE 13

.

Light On/Off Button ( L )

On/Off switch for the halogen  lights.    Push the button in to turn 

the light ON, push again to turn the light OFF.

Blower 

On/Off and Speed Buttons ( 1, 2, 3 )

Push button (1) to turn ON and OFF the blower.  This button 

must be pushed in for the blower to operate regardless of 

speed  chosen.    Button  (1)  operates  the  blower  on  LOW 

speed.  Push button (2) for MEDIUM speed.  Push button (3) 

for HIGH speed.

Cleaning

The stainless steel grease filters should be cleaned frequently in 

hot detergent solution or washed in the dishwasher.   Stainless 

steel  cleaner  should  be  used  on  stainless  rangehoods.  

Abrasives and scouring agents can scratch stainless steel 

finishes and should not be used to clean finished surfaces.

Replacing the Lamps

Before attempting to replace the lamps, make sure that the 

light switch is turned off.  Remove the 2 screws 

(as indicated 

in FIGURE 14)

 that hold the light support and gently pull the 

support down from the hood.  Remove the lamp from the light 

support and replace with new lamp.  Replace the light support 

and fix it into place with the 2 screws. 

An alternative method to replace the lamps is to use a 1 

1/4" suction cup (

FIGURE 15

). Attach the suction cup to 

the bulb and pull firmly down on the bulb and replace with 

a new lamp. 

FIGURE 12

2.

 Turn the power supply on.  Turn on blower and lights.  If the 

rangehood does not operate, check that the circuit breaker is not 

tripped or the house fuse blown.  If the unit still does not operate, 

disconnect the power supply and check that the wiring connec

-

tions have been made properly.

FIGURE 13

FIGURE 14

USE  AND  CARE  INFORMATION

This rangehood system is designed to remove smoke, cooking 

vapors and odors from the cooktop area.

For Best Results

Start the rangehood several minutes before cooking to develop proper 

airflow.  Allow the unit to operate for several minutes after cooking is 

complete to clear all smoke and odors from the kitchen.

Blower Indicator 

Light  ( I )

Lights  up  to  indicate 

blower is ON.

FIGURE 15

WIRING  DIAGRAM

• This rangehood uses 20 watt MR-11 halogen lamps w/ cover.

Summary of Contents for STILO Wall Mount Canopy Rangehood

Page 1: ...Title 24 HUD Part 280 Four wire power supply must be used and the appliance wiring must be revised See Electrical Requirements LISEZ BIEN CETTE FICHE AVANT D INSTALLER LA HOTTE AVERTISSEMENT POURMINI...

Page 2: ...ral Ventilating Use Only Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors WARNING TO REDUCE THE RISK OF FIRE ELECTRI CAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING InstallationW...

Page 3: ...as perforer un autre fil lectrique Une ventilateur vacuation ext rieure doit tre raccord e l ext rieur AVERTISSEMENT Le syst me d vacuation DOIT sortir l ext rieur N VACUEZ PAS le conduit soit dans un...

Page 4: ...RTS NEEDED FOR INSTALLATION 2 Conduit Connectors Power Supply Cable 1 Wall or Roof Cap All Metal Ductwork OPTIONAL ACCESSORIES AVAILABLE Backsplash Choose either 24 or 30 high mounts to the wall benea...

Page 5: ...eiling installations the High Ceiling Chimney Kit includesanew40 upperchimneywhichwould replace the 16 1 8 upper chimney that came with the hood upper chimney cover lower chimney cover canopy x distan...

Page 6: ...eet varying ceiling heights as indicated in FIGURE 4B For ductless installations the chimneys can be adjusted for ceilings between 7 9 5 8 and 8 9 3 4 depending on the distance between the bottom of t...

Page 7: ...n FIGURE 5A or 5B and install the MOUNTING SCREWS into the wall leaving about 1 4 gap between the wall and the head of the screw 8 For ducted installations determine and make all necessary cuts in the...

Page 8: ...e grounding lead to the green screw provided Attach the White lead of the power supply to the White lead of the rangehood with a twist on type wire con nector Attach the Black lead of the power supply...

Page 9: ...should not be used to clean finished surfaces Replacing the Lamps Before attempting to replace the lamps make sure that the light switch is turned off Remove the 2 screws as indicated in FIGURE 14 th...

Page 10: ...umbing 2 Service calls to repair or replace range hood light bulbs fuses or filters Those consumable parts are excluded from warranty coverage 3 Repairs when your range hood is used for other than nor...

Page 11: ...toit Conduit en m tal ACCESSOIRES POUR L INSTALLATION Dosseret 30 po X 24 po haute part 6098835 Acier Inoxydable 30 po X 30 po haute part 620000095 Acier Inoxydable 36 po X 24 po haute part 6098815 A...

Page 12: ...diff rentes hauteurs de plafond entre 7 pi 4 3 4 po et 8 pi 9 3 4 po regardez la distance entre la hotte et la table de cuisson X en FIGURE 4A Celas accomplitenutilisantplus ou moins du couvercle de l...

Page 13: ...t r glable pour diff rentes hauteurs de plafond entre 7 pi 9 5 8 po et 8 pi 9 3 4 po regardez la distance entre la hotte et la table de cuisson X en FIGURE 4B Cela s accomplit en utilisant plus ou moi...

Page 14: ...r et la t te de la vis 8 Pour les installations avec conduit d terminer et faire toutes les coupes n cessaires dans le mur pour les conduits Installer les conduits avant la hotte 9 D terminerl emplace...

Page 15: ...t jaune et vert sous la vis de mise la terre verte Replacer le couvercle du compartiment de c blage 2 Installer la CHEMIN E SUP RIEURE C de la FIGURE 10 Elargir l g rement les deux bords lat riaux de...

Page 16: ...ansunesolutiond eauchaudeetded tergent ou mettre au lave vaisselle Utiliser un nettoyant pour l acier inoxydable sur les hottes en acier inoxydable Ne pas utiliser de produits abrasifs ou de r curants...

Page 17: ...e maison ou pour corriger votre c blage ou votre syst me de plomberie 2 Les appels de service pour remplacer ou r parer les ampoules les fusibles ou les filtres de votre hotte de cuisini re 3 Les r pa...

Reviews: