33
CFM ADJUSTMENT < 295CFM
To start the process make sure the hood lights are On and motor is Off.
1) Press and hold
T1
for 5 seconds until
T1 - T2 - T3 - T4
flash for 3 seconds.
2) Press
T1
until the LED's flash.
3) Press
T1
again to confirm and
T1 - T2 - T3 - T4
flash for 3 seconds (pressed
within 10 seconds).
4) The four LED's will flash again to confirm you have finished the CFM adjustment
to less than 295 CFM.
5) Apply the under 295 CFM label inside the hood (behind the grease filters) near
the rating label for inspection and on the front of your installation/user manual.
6) To confirm your setting for inspection,
T1
and
T2
buttons will always operate
the hood at speed 1
or speed 2. The highest speed (
T3
) and the intensive speed
(
T4
), will also no longer operate.
Note
:
T2
and
T3
buttons will now operate at the same level and the Intensive Speed
will be deactivated.
Attention
: When the under 295 CFM adjustment is completed, it is no longer
possible to change this setting to the original CFM level.
ATTENTION
: For a correct functioning of the FABER CLOUD APP, when this
procedure is completed disconnect the plug from the power supply.and reconnect
it again.
Summary of Contents for STILO SUPREMA STSP30SSV
Page 6: ...6 RANGE HOOD DIMENSIONS DRAFT 06 30 36...
Page 7: ...7 INSTALLATION HEIGHT REQUIREMENTS MIN 24 OVER ELECTRIC MIN 30 OVER GAS Min 24 Min 30...
Page 9: ...9 B A F C D E...
Page 18: ...18 CHOOSING VENTING METHOD VENTED RECIRCULATING Go to Pg 19 Go to Pg 23...
Page 46: ...46 DIMENSIONS DE LA HOTTE DRAFT 06 30 36...
Page 49: ...49 B A F C D E...
Page 58: ...58 CHOIX DE LA M THODE DE VENTILATION VENTIL RECIRCULATION Allez la page 59 Allez la page 63...
Page 86: ...86 DIMENSIONES DE LA CAMPANA EXTRACTORA DRAFT 06 30 36...
Page 89: ...89 B A F C D E...
Page 122: ......
Page 123: ......