UK/IRL
19
UK/IRL
18
4.3 Fitting the firebox
Points of attention for placement:
- If possible, first locate the appliance before assembling the flue.
- If this is not possible then always use an extendible pipe before
connection onto the appliance.
1.
Position the firebox in the fireplace opening. You can adjust the
height with the 4 adjustable feet.
2
Make the gas connection according to the instructions (also see gas
connection, chapter 4.1).
3. Assemble the flue system onto the firebox (see chapter 5).
4. If necessary, place the DC convection system (also consult the
instruction belonging to the DC construction set).
5. Isolate the firebox with a ceramic blanket (25 mm). Preferred choice
for insulation is unbound insulation wool (at 1000 °C gives no
smell).
6. Spread, the bag of embers (imitation ashes) provided with the
appliance over the burner. Do not use more than the quantity
supplied. The embers glow on low setting.
ceramic blanket
ceramic
blanket
ceramic
blanket
ceramic
blanket
ceramic
blanket
fig. 9
4.2 Preparing the appliance (continuing)
4.2.3 Model Silva
1. Open the door by pressing against the door at the bottom right
and remove the door.
2. Remove the front, by unscrewing the four screws (see fig. 7).
3. Remove the glass by disassembling the securing frame (unfasten
the two screws on the bottom of the frame and remove the 2
screws on top of the frame) (see fig. 7).
4. Take the box with the log set out of the combustion chamber.
5. Place the right flue restrictor in the combustion chamber. To
determine the right flue restrictor, see chapter 3. (Standard
preinstalled 45 mm).
fig. 8 placing flue restrictor
fig. 7