Once gas is available at the pilot, continued rotation anti-clockwise
will cause the piezo igniter to spark. This is accompanied by a click
at the valve and should result in the pilot burner igniting.
Once the pilot is lit, the control knob should be held pressed in for
10 seconds. In this time the pilot flame will have heated the flame
supervision thermocouple sufficiently to operate a hold-on magnet
within the valve.
Now turn the control knob A to the
position. This allows gas to
enter control knob B.
Knob B
The
{
is the OFF position preventing gas entering the main burner if
the pilot is lit.
The knob should be turned slowly anticlockwise. This allows gas to
enter the burner and be ignited by the pilot flame. Once ignition has
taken place, the fire may be set to any level between min. and max.
by adjusting the control knob B.
10.2 To light
1.
Push in and turn the control knob (A) from
{
anticlockwise to
the setting
(small flame). You will hear an ignition click. Check
that the pilot is lit (if not repeat).
2. Continue to hold in the control knob for a further ten seconds to
ensure that the pilot flame is stable.
3. Release the knob. The pilot should remain alight.
4. Turn the control knob A to the
position.
5. Turn knob B slowly anticlockwise, the fire should then ignite.
6. Adjust flames to the required level.
10. CONTROLLING THE APPLIANCE
10.1 Lighting the fire
If the main burner or pilot light are extinguished for any reason,
do
not attempt to relight the pilot within 5 minutes.
Contact a qualified
installer when the appliance goes off regularly.
We advise you to leave the pilot flame on. Leaving the pilot flame on
reduces the amount of condensation when starting the appliance and
increase the life time of the appliance.
The control valve is behind the door or ash pan cover.
Open the door by pressing against the door at the bottom right
(Silva only).
With control button A you can light the pilot. With the control
button B you can adjust the height of the flames (see fig. 24).
Knob A
The
{
is the OFF position preventing any gas from passing through
the control valve to either the pilot burner or to the main burner. By
pressing the knob in it is possible to turn it anticlockwise. The first
function is to turn on the gas to the pilot- this occurs just before
reaching the
|
position (if the fire has not been lit for some time it
may be necessary to hold the knob in this position for some seconds
to clear the air from the pipe and allow gas to reach the pilot burner).
fig. 24 control unit
A
B