Faber Respect Premium OC Installation Manual Download Page 12

 

Installation manual Respect Premium OC

 

 

12 < 

<

 

<

 

4.7

 

Installing the flue pipes 

Install the flue pipes according to the installation 
manual supplied with the appliance (40011968)! 

 

The distance to combustible materials 
must be min. 50mm, calculated from the 
outside of the flue pipe. 

 

Never start immediately with length-
adjustable concentric flue pipe on the 
appliance. 

 

Horizontal sections should be installed to 
allow a slope towards the appliance  

(3 degrees). 

 

Build the system from the appliance. If 
this is not possible you can make use of an 
extendable adapter section. 

 

For fitting of the flue system, the 0,5m 
length-adjustable pipe must be used. 
Make sure that the inner pipe is always 
15mm longer than the outer pipe. Wall- 
and roof terminal can also be cut. These 
components must be secured with a self-
tapping screw. 

4.8

 

Constructing the false chimney 

Before positioning the false chimney, we advise to 
perform a functional test with the fireplace as 
defined in chapter 7 “Checking the installation”. 
 
False chimney 

 

Construct the false chimney of non-
combustible material in combination with 
metal profiles or of masonry/concrete 
blocks. 

 

Always use a lintel or reinforcing bars 
while bricking the false chimney. They 
should not be placed directly on the 
fireplace. 

 

Make sure that the fireplace never 
functions as a load-bearing construction, 
because of the expansion of the fireplace 
through warmth. 

 
Ventilation 
Correct ventilation prevents damaging overheating 
of the gas control block and its electronics and also 
limits the temperature of the convection air. Use 
the (optional) supplied Faber ventilation grids 
(article number A9296400) or a similar alternative 
with a minimum free passage of 200cm² per grid, 
in the space above the fire, when building the false 
chimney. Within the false chimney, an horizontal 
screen plate, made of non-combustible material, 
must be installed just above the ventilation 
openings. (see fig. 1.0-A). 
 
 
 

5

 

Installing glass 

 

 

Please note! 
Before installing the front glasses, install the 
side glasses first! 

5.1

 

Side glasses 

For cleaning only it’s not necessary to remove the 
side glass. 

 

 

Place a suction cup on the side glass. 

 

Lower the side glass into the space behind 
the build-in frame (fig. 3.1). 

 

Hold the glass tilted at an angle and insert 
the glass into the upper glass groove (fig. 
3.2). 

 

Now lower the side glass into the lower 
glass groove. 

 
For removing the glass repeat the steps in reverse 
order. 

 

 

Please note! 
Avoid fingerprints on the glass, these are no 
longer removable once the fire is used. 

5.2

 

Front glasses 

 

 

Please note! 

 

First install the side glasses (see chapter 
5.1). 

 

First install the right front glass (with 
Faber logo). 

 

The white stopper in the glass groove on 
the right corner holds the right front glass 
in place (see fig. 3.5). 

 
Front glass right (with Faber logo): 

 

Place the suction cups on the front glass. 

 

Insert the front glass into the upper glass 
groove and lower the glass into the lower 
glass groove (see fig. 3.3). 

 
Front glass left: 

 

Place the suction cups on the front glass. 

 

Insert the front glass into the upper glass 
groove and lower the glass into the lower 
glass groove (see fig. 3.4). 

 

Check whether all the glasses at the 
corners are properly aligned. 

 

For removing the glass repeat the steps in reverse 
order. 

 

 

Please note! 
Avoid fingerprints on the glass, these are no 
longer removable once the fire is used. 

Summary of Contents for Respect Premium OC

Page 1: ...Installation manual Respect Premium OC ENG 40011335 2009 ...

Page 2: ...Installation manual Respect Premium OC 2 ...

Page 3: ...Installation manual Respect Premium OC 3 ...

Page 4: ...Installation manual Respect Premium OC 4 1 0 1 1 1 2 1 3 1 4 1 5 1 6 A A ...

Page 5: ...Installation manual Respect Premium OC 5 1 7 1 8 1 9 2 0 Y X B C D ...

Page 6: ...Installation manual Respect Premium OC 6 2 1 3 1 3 2 3 3 3 4 ...

Page 7: ...Installation manual Respect Premium OC 7 3 5 3 6a 3 6b 3 6c 3 6d 4 0 A B B A ...

Page 8: ...Installation manual Respect Premium OC 8 ...

Page 9: ...e It is advisable to always install a screen for the fireplace if children elderly or disabled people are present in the same room as the fireplace If regularly vulnerable persons can be present in the room without supervision sufficient protection must always be placed around the fireplace This appliance must be installed according with the rules in force and used only in a sufficiently space The...

Page 10: ...ts the local regulations regarding pollution and ventilation openings Please note For proper functioning the outlet must at least be 0 5m away from Corners of the building Roof overhangs and balconies Roof edges with the exception of the ridge edge see chapter 15 C11 outlet via facade Through a wall or façade use a Faber wall outlet Depending on the flue calculation this can be 100 150mm or 130 20...

Page 11: ...ight of 780mm With the upper part removed the appliance can be transported on its back fig 1 4 Please note The transport plate may only be removed after the fireplace has been fixed to the wall see fig 1 8 4 6 Positioning the fireplace Take into account the installation requirements see chapter 3 Place the fireplace at the right place and level it see fig 1 9 D Rough height adjustment With the adj...

Page 12: ...optional supplied Faber ventilation grids article number A9296400 or a similar alternative with a minimum free passage of 200cm per grid in the space above the fire when building the false chimney Within the false chimney an horizontal screen plate made of non combustible material must be installed just above the ventilation openings see fig 1 0 A 5 Installing glass Please note Before installing t...

Page 13: ...ame distribution is good Move or remove any ash material to create a nice glow bed Install the front glasses and check the fire image 6 2 Pebbles Grey stones See the supplied decoration instruction card or chapter 18 2 or 18 3 Divide the pebbles grey stones over the entire bottom Avoid a double layer Please note Keep the pilot flame and 2nd thermocouple free from pebbles grey stones Start the fire...

Page 14: ...must not be greater than 1 100 Example CO2 is 4 and CO is 400ppm measured at the highest point If the ratio is greater than 1 100 or flue gases are measured in the air supply check the points in section 7 1 8 Instructions for client Recommend that the fire should be checked annually by a qualified specialist to ensure the safe use and to guarantee a long service life Provide instructions on the op...

Page 15: ...on in the drawings fig 12 1 12 2 and 12 3 Total Horizontal Length THL THL is the Total Horizontal Length and consists of elbows and pipes entirely in the horizontal plane See elbows I K and Q and the elements H J L M P and R fig 12 1 and 12 2 Horizontal length The Horizontal Length consists of the elements H J L M P and R fig 12 1 and 12 2 Elbows 90 in the horizontal plane Horizontal elbows are el...

Page 16: ...0 x x x x x x x x x x 9 60 20 x x x x x x x x x x 10 60 20 x x x x x x x x x x 11 70 20 x x x x x x x x x x 12 70 20 x x x x x x x x x x 13 70 20 x x x x x x x x x x 14 70 20 x x x x x x x x x x 15 80 20 x x x x x x x x x x 16 80 20 x x x x x x x x x x 17 80 20 x x x x x x x x x x 18 80 20 x x x x x x x x x x 19 80 20 x x x x x x x x x x 20 80 20 x x x x x x x x x x 21 80 20 x x x x x x x x x x 22...

Page 17: ... 40 80 40 80 40 80 40 70 40 70 40 70 40 65 40 x x 12 80 40 80 40 80 40 80 40 80 40 70 40 70 40 70 40 65 40 x x 13 85 40 80 40 80 40 80 40 80 40 70 40 70 40 70 40 65 40 x x 14 85 40 85 40 80 40 80 40 80 40 70 40 70 40 70 40 65 40 x x 15 85 40 85 40 80 40 80 40 80 40 70 40 70 40 70 40 65 40 x x 16 85 40 85 40 80 40 80 40 80 40 70 40 70 40 70 40 65 40 x x 17 85 40 85 40 80 40 80 40 80 40 70 40 70 40 ...

Page 18: ...Installation manual Respect Premium OC 18 12 Examples flue materials ...

Page 19: ... 5 Flue length 2m or more 2 Bend 90 0 1 Bend 45 30 or 15 0 2 Roof terminal 1 Wall terminal 0 Total Vertical Height TVH measured height rounded value meter meter Total Horizontal Length THL Calculation Part number x value result rounded value Total Length in meters x 1 90 Bend vertical to horizontal x 0 4 45 Bend vertical to horizontal x 0 2 90 Bend in horizontal direction x 1 5 45 Bend in horizont...

Page 20: ... installation is not possible Solution Change the TVH or THL Results Restrictor size Value for the comma mm Extra information Value behind the comma mark Install the air restrictor plate see installation manual 0 1 Install adapter 100 150 direct on top of the fire 0 2 In case of wall terminal install adapter 100 150 before the last bend in case of roof terminal just before the terminal 0 3 In case...

Page 21: ...D D Energy efficiency index EEI 73 73 73 Type heating output control room temperature no no no no no yes Glen Dimplex Benelux Saturnus 8 Heerenveen The Netherlands With mechanical control of the room temperature by thermostat Control of room temperature with open window detection no With electronic control of the room temperature With electronic control of the room temperature plus day time switch...

Page 22: ...sition outlet Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Short...

Page 23: ...Installation manual Respect Premium OC 23 16 Troubleshooting guide ...

Page 24: ...Installation manual Respect Premium OC 24 ...

Page 25: ...Installation manual Respect Premium OC 25 17 Dimensional drawings 17 1 Respect Premium OC ...

Page 26: ...Installation manual Respect Premium OC 26 17 2 Remote access door article number A9299463 ...

Page 27: ...Installation manual Respect Premium OC 27 17 3 Ventilation grid article number A9296400 ...

Page 28: ...Installation manual Respect Premium OC 28 18 Decoration instruction card 18 1 Log set ...

Page 29: ...Installation manual Respect Premium OC 29 ...

Page 30: ...Installation manual Respect Premium OC 30 18 2 Pebbles 18 3 Grey stones ...

Page 31: ...Installation manual Respect Premium OC 31 ...

Page 32: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...