Installation manual Odense

 

19 < 

<

 

<

 

 

 

 

Summary of Contents for Odense

Page 1: ...Installation manual Odense ENG 40010898 2010 ...

Page 2: ...Installation manual Odense 1 ...

Page 3: ...Installation manual Odense 2 ...

Page 4: ...Installation manual Odense 3 1 1 1 2 1 3a 1 3b 1 4 A ...

Page 5: ...Installation manual Odense 4 1 5 1 6 1 7 1 8 2 0 2 1 1 2 ...

Page 6: ...Installation manual Odense 5 2 2 2 3 ...

Page 7: ...sable to always install a screen for the fireplace if children elderly or disabled people are present in the same room as the fireplace If regularly vulnerable persons can be present in the room without supervision sufficient protection must always be placed around the fireplace This appliance must be installed according with the rules in force and used only in a sufficiently space The appliance m...

Page 8: ...91 existing chimney For an existing chimney use a Faber chimney outlet with a diameter of 100 150mm In this case the existing chimney acts as air inlet an inserted flexible stainless steel pipe discharges the flue gas The top Faber chimney cover plate and the bottom Faber chimney connection set should be airtight Depending on the calculated flue diameter you must use a flexible stainless steel pip...

Page 9: ...liance If this is not possible you can make use of an extendable adapter section For fitting of the flue system the 0 5m length adjustable pipe must be used Make sure that the inner pipe is always 15mm longer than the outer pipe Wall and roof terminal can also be cut These components must be secured with a self tapping screw 5 Removing glass 5 1 Front glass Remove the cast iron frame To do this pu...

Page 10: ... manual and test all burner possibilities 7 1 Checking the flame image Let the fireplace burn for at least 20 minutes at highest setting and check the flame for flame distribution colour of the flames If one or both points are not acceptable then check The position of the logs and or the amount of ash material The pipe connections for leaks in case of blue flames That the correct flue restrictor i...

Page 11: ...he fireplace and represents a certain value fig 12 1 12 2 and 12 3 A N and F You can find this value in the upper row of the restrictor table Total Vertical Height TVH TVH is the height difference measured from the top of the appliance to the outlet This can be measured or determined in the building plan For clarification see also the TVH indication in the drawings fig 12 1 12 2 and 12 3 Total Hor...

Page 12: ...ted Then adjust TVH or THL If a value is indicated check that the calculated STL value is not lower than indicated in the restrictor table In this case STL must be adjusted The value found indicates the width of the flue restrictor to be placed 0 means no flue restrictor Generally a 30mm flue restrictor is installed fig 1 4 A ...

Page 13: ...0 60 00 60 00 50 00 40 00 x x x x 12 65 10 65 00 65 00 60 00 60 00 50 00 40 00 x x x x 13 65 10 65 00 65 00 60 00 60 00 50 00 40 00 x x x x 14 65 10 65 00 65 00 60 00 60 00 50 00 40 00 x x x x 15 65 10 65 00 65 00 60 00 60 00 50 00 40 00 x x x x 16 65 10 65 00 65 00 60 00 60 00 50 00 40 00 x x x x 17 65 10 65 00 65 00 60 00 60 00 50 00 40 00 x x x x 18 65 10 65 00 65 00 60 00 60 00 50 00 40 00 x x...

Page 14: ...Installation manual Odense 13 12 Examples flue materials ...

Page 15: ...e length 2m or more 2 Bend 90 0 1 Bend 45 30 or 15 0 2 Roof terminal 1 Wall terminal 0 Total Vertical Height TVH measured height rounded value meter meter Total Horizontal Length THL Calculation Part number x value result rounded value Total Length in meters x 1 90 Bend vertical to horizontal x 0 4 45 Bend vertical to horizontal x 0 2 90 Bend in horizontal direction x 1 5 45 Bend in horizontal dir...

Page 16: ...llation is not possible Solution Change the TVH or THL Results Restrictor size Value for the comma mm Extra information Value behind the comma mark Install the air restrictor plate see installation manual 0 1 Install adapter 100 150 direct on top of the fire 0 2 In case of wall terminal install adapter 100 150 before the last bend in case of roof terminal just before the terminal 0 3 In case of ro...

Page 17: ... Energy efficiency index EEI 89 89 89 Type heating output control room temperature no no no no yes no Diameter outlet inlet 100 150 Technical data Type indication s Odense Type appliance C11 C31 C91 Gas connection 3 8 Indirect heating functionality no Category II2H3 Gas rate at full mark Power requirement for permanent pilot light if applicable Ppilot 0 15 0 15 kW Other control options One step he...

Page 18: ... outlet Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Short roof ...

Page 19: ...Installation manual Odense 18 16 Troubleshooting guide ...

Page 20: ...Installation manual Odense 19 ...

Page 21: ...Installation manual Odense 20 ...

Page 22: ...Installation manual Odense 21 17 Dimensional drawings 17 1 Odense ...

Page 23: ...Installation manual Odense 22 17 2 Gas connection ...

Page 24: ...Installation manual Odense 23 18 Decoration instruction card ...

Page 25: ...Installation manual Odense 24 ...

Page 26: ...Installation manual Odense 25 ...

Page 27: ...Installation manual Odense 26 ...

Page 28: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...