![Faber Odense Installation Manual Download Page 9](http://html.mh-extra.com/html/faber/odense/odense_installation-manual_535932009.webp)
Installation manual Odense
8 <
<
<
<
See fig. 1.3b for the wiring diagram with I.T.C
(optional):
A = Adapter (6 V)
B = Gas valve
C = Receiver
D = Ignition pin
E = I.T.C. (Intelligent Technical Controller)
4.3
Smart Home installation
Please note!
This is only possible if the fire is equipped
with I.T.C!
The controller can be connected to an external
source, such as a Domotica system, by using a
Faber Interface Unit (article number A9323000).
4.4
Preparing the fireplace
Remove the fireplace from its packaging.
Remove the glass and any mouldings,
store them at a safe place and remove the
packaged parts from the fireplace.
Prepare the gas connection on the gas
valve.
4.5
Positioning the fireplace
Take into account the installation requirements
(see chapter 3). Place the fireplace at the right
place and level it. Observe the minimum distances
around the fireplace (See chapter 3).
Please note!
Only a minimal adjustment of a few
millimetres is possible.
4.6
Installing the flue pipes
Install the flue pipes according to the installation
manual supplied with the appliance (40011968)!
The distance to combustible materials
must be min. 50mm, calculated from the
outside of the flue pipe.
Never start immediately with length-
adjustable concentric flue pipe on the
appliance.
Horizontal sections should be installed to
allow a slope towards the appliance
(3 degrees).
Built the system from the appliance. If this
is not possible you can make use of an
extendable adapter section.
For fitting of the flue system, the 0,5m
length-adjustable pipe must be used.
Make sure that the inner pipe is always
15mm longer than the outer pipe. Wall-
and roof terminal can also be cut. These
components must be secured with a self-
tapping screw.
5
Removing glass
5.1
Front glass
Remove the cast iron frame. To do this,
push the frame upwards and pull the
bottom towards you (fig. 1.5).
Place the suction cups (fig. 1.8).
Remove the glass clamps (fig. 1.6).
Remove the front glass (fig. 1.7).
For replacing the glass repeat the steps in reverse
order.
Please note!
Avoid fingerprints on the glass, these are no
longer removable once the fire is used.
5.2
Side glass
For cleaning only it’s not necessary to remove the
side glass.
Remove the front glass. (See chapter 5.1);
Remove the log set;
Remove the 2 log set supports (fig. 2.0);
Remove the burner plate (fig. 2.1);
Place a suction cup;
Remove the 4 glass clamps (fig. 2.2);
Remove the side glass (fig. 2.3).
For replacing the glass repeat the steps in reverse
order.
Please note!
Avoid fingerprints on the glass, these are no
longer removable once the fire is used.
6
Placing decoration material
It is not permitted to use other or to add more
material in the combustion chamber.
See the supplied decoration instruction card or
chapter 18.
Place the log set;
Divide the ash material between the logs,
don’t cover the air intake (perforated
parts) at the back.
Please note!
Keep the pilot flame free from ash material.
Start the fireplace as described in the user
manual.
Summary of Contents for Odense
Page 1: ...Installation manual Odense ENG 40010898 2010 ...
Page 2: ...Installation manual Odense 1 ...
Page 3: ...Installation manual Odense 2 ...
Page 4: ...Installation manual Odense 3 1 1 1 2 1 3a 1 3b 1 4 A ...
Page 5: ...Installation manual Odense 4 1 5 1 6 1 7 1 8 2 0 2 1 1 2 ...
Page 6: ...Installation manual Odense 5 2 2 2 3 ...
Page 14: ...Installation manual Odense 13 12 Examples flue materials ...
Page 19: ...Installation manual Odense 18 16 Troubleshooting guide ...
Page 20: ...Installation manual Odense 19 ...
Page 21: ...Installation manual Odense 20 ...
Page 22: ...Installation manual Odense 21 17 Dimensional drawings 17 1 Odense ...
Page 23: ...Installation manual Odense 22 17 2 Gas connection ...
Page 24: ...Installation manual Odense 23 18 Decoration instruction card ...
Page 25: ...Installation manual Odense 24 ...
Page 26: ...Installation manual Odense 25 ...
Page 27: ...Installation manual Odense 26 ...