14
as prior to the service.
6. Reassemble in the reverse order as above.
BLOWER/FAN REPLACEMENT
WARNING:
Disconnect power before attempting any
maintenance or cleaning to reduce the risk of electric
shock or damage to persons.
CAUTION:
If unit was operating prior to servicing allow
at least 10 minutes for lights and heating elements to cool
off to avoid accidental burning of skin.
Tools required:
Phillips head screwdriver.
Needle nosed pliers.
CAUTION:
Follow “Preparation for Service” instructions
before proceeding.
1. Remove the 10 screws that secure the heater assem-
bly retaining bracket to the unit. Remove the bracket
and set aside.
2. Locate and remove the 4 screws that secure the as-
sembly to the unit.
CAUTION:
When removing the blower assembly mount-
ing screws support the assembly to prevent any damage to
the unit.
3. Disconnect the wiring connections noting their original
locations.
!
NOTE:
Using a flat head screwdriver gently pry be-
tween the end of the connectors and the blower/fan to
release the wires.
4. Properly orient the new blower/fan assembly and con-
nect all of the wiring connections.
5. Reassemble in the reverse order as above.
Figure 9
Retaining
Bracket
Mounting Screws