background image

 

User manual Symax

 

3 < 

<

 

<

 

<

 

 

Dear user 

Congratulations on your purchase of a Faber fire! A 
quality product from which you will experience 
warmth and atmosphere for many years. We 
recommend that you read this manual carefully 
before using the fireplace. If any problem arises 
despite our strict quality control, you can always 
contact your dealer or Glen Dimplex Benelux B.V. 

 

For any warranty claims, it is essential you first 
register your fireplace. During this registration, 
you’ll find all information regarding our warranty. 
 
Details about your fire can be found on page 1 of 
this user manual. 
 
You can register your fire at: 

www.faber-fires.eu 

 
Glen Dimplex Benelux B.V. 
Address: Saturnus 8 
 

NL-8448 CC 
Heerenveen 

Tel: 

+31 (0)513 656 500  

Email:  [email protected] 
Info: 

www.faber-fires.eu

 

 

 

Introduction 

Installation and maintenance of the appliance must 
be carried out by a professional with proven 
knowledge and competence. A professional takes 
into account all technical aspects such as heat 
radiation and gas connection as well as flue gas 
exhaust requirements. 
 
Where the installation instructions are not clear, 
national/local regulations must be followed. 
 

 

Check 

Check the fire for transport damage and 
immediately report any damage to your supplier. 

 

CE Declaration  

We hereby declare that Glen Dimplex Benelux B.V. 
released Faber gas-atmosphere heating appliance 
by its design and construction method complies 
with the Regulation (EU): 2016/426 and (EU) 
2015/1188. 

 

Safety instructions for the user 

 

 

Please note! 
It is advisable to always install a screen for the 
fireplace if children, elderly or disabled people 
are present in the same room as the fireplace. 
If regularly vulnerable persons can be present 
in the room without supervision, sufficient 

protection must always be placed around the 
fireplace. 

 

As a fire is a source of heat, hot air 
circulation is created. As a result of 
natural air circulation, moisture and not 
yet cured volatile components from paint, 
building materials and carpeted floors are 
included in this air circulation. These parts 
can settle as soot on cold surfaces. The 
moment, using the fire for the first time, 
depends on various circumstances. 
Consult your installer/dealer about this 
matter. 

 

The appliance is designed for atmospheric 
and heating purposes, meaning that all 
visible surfaces, including the glass, can 
become hotter than 100 ° C. An exception 
for free standing models is the underside 
of the fireplace and the control buttons. 

 

Do not use the remote control and/or App 
outside the room where the fire is 
situated. Be sure that you are always 
aware of the situation around the fire 
when it is operated. 

 

The fire cannot be used when: the glass is 
damaged or removed or when the 
combustion chamber is open. 

 

Do not place flammable materials inside 
the combustion chamber. 

 

Do not place extra imitation wood or 
other material on the burner or in the 
combustion chamber. 

 

Do not place any combustible materials 
within 0,5m of the radiation area of the 
fire.  

 

Do not allow children to use the remote 
control without supervision. 

 

 

Using the fire for the first time 

Provide extra ventilation and open all the windows 
of the room during the initial start-up of the fire. 
Let the fire burn at the highest setting for a few 
hours so that the paint gets the chance to harden 
and any released vapours are safely removed. Keep 
vulnerable people and pets out of this room during 
this process 
 

 

Cleaning and maintenance 

The device must be cleaned and checked by a 
qualified specialist to ensure the safe use and to 
guarantee a long service life. 
The outside of the fire can be cleaned with a clean 
damp cloth. 
 
Cleaning of the glass 
Remove the glass as described in the installation 
instructions. The glass can be cleaned with Faber 

Summary of Contents for Mertik

Page 1: ...User manual Symax Mertik ENG 40011927 1939...

Page 2: ...l number This user manual is intended for the following gas fires MatriX 450 500 I II III MatriX 450 650 I II III MatriX 800 500 I II III MatriX 800 650 I II III MatriX 1050 500 I II III MatriX 1050 6...

Page 3: ...User manual Symax 2 1 1 1 2 1 3 1 4 1 5 1 6 2 0...

Page 4: ...ed around the fireplace As a fire is a source of heat hot air circulation is created As a result of natural air circulation moisture and not yet cured volatile components from paint building materials...

Page 5: ...air them again Remote control The battery indication in top right corner of the display screen indicates the status of the batteries fig 2 0 After replacing the batteries the settings of the Thermosta...

Page 6: ...o key operation Standard is one key operation To set this immediately press the key for 10 seconds after placing the batteries and wait until 1 or 2 flashes Release the key when the desired number of...

Page 7: ...nfirm press the key or wait Now the light effect is adjusted Extended functions Countdown timer Please note The countdown timer works in Manual and Thermostatic mode only Max countdown time is 9 hours...

Page 8: ...e key until OFF appears and the temperature flashes Press the or key to set the switch off temperature To confirm press the key Set day ALL flashes Press the or key to set the right day or period To c...

Page 9: ...ast the ON position fig 1 6 This causes a rattling sound Please note When step burner you can t switch between narrow and wide manually Fault codes remote control Fault code Duration time fault code o...

Page 10: ...User manual Symax 9...

Page 11: ...User manual Symax 10...

Page 12: ......

Reviews: