Installation manual MatriX 800-1050x500 RD,ST H
9 <
<
<
<
This appliance must be built into an
existing or new false chimney.
For appliances with flexible gas pipes, the
control unit (fig. 1.2) is mounted at the
bottom of the crate. Detach and mount it
together with the control box and
remote access door in as low as possible
position in the false chimney. (See
supplied instruction manual 40011721).
(To prevent damage to cables and pipes
during transport, they are bound together
by tie wraps. Remove these to ensure
proper operation of the appliance.)
The MatriX 800-1050x500-RD,ST comes
standard with a 2 meter pipe set (article
number 20901530). For connecting the
appliance to the gas connection.
3.2
False chimney
1.
The false chimney should be of non-
combustible material.
2.
The space above the fire should always be
ventilated using grids with minimal free
passage of 200cm² per grid.
3.
The false chimney construction should not
rest on the build-in frame of the fireplace.
3.3
Discharge and outlet requirements
First, carry out a flue calculation (see chapter 11)
and adjust the correct restrictor value before
installing the outlet! (Generally the flue restrictor is
adjust to 60).
For supply and discharge always use the
prescribed and to be supplied Faber flue
materials. Please contact Glen Dimplex
Benelux B.V.. Only with use of these
materials Faber can guarantee proper
performance.
The distance to combustible materials
must be min. 50mm, calculated from
outside of the flue material (EN 1856-1
T600 N1 D Vm – L20040 O(50)).
Outlets (fig. 1.3)
The balanced flue pipe for combined air supply and
discharge can use a wall terminal or a roof
terminal. Verify that the desired outlet meets the
local regulations regarding pollution and
ventilation openings.
Please note!
For proper functioning, the outlet must at
least be 0,5m away from:
Corners of the building;
Roof overhangs and balconies;
Roof edges (with the exception of the
ridge edge, see chapter 15).
C11, outlet via facade
Through a wall or façade, use a Faber wall outlet.
130/200mm.
C31, outlet via roof
For a (flat) roof, use a Faber roof outlet with a
diameter of 100/150mm.
C91, existing chimney
For an existing chimney, use a Faber chimney
outlet with a diameter of 100/150mm.
In this case the existing chimney acts as air inlet an
inserted flexible stainless steel pipe discharges the
flue gas. The top (Faber chimney cover plate) and
the bottom (Faber chimney connection set) should
be airtight.
Depending on the calculated flue diameter, you
must use a flexible stainless steel pipe of
Ø100mm (article number AJ005503) or Ø130mm
(article number AJ005603) as specified by Faber.
For this, contact Glen Dimplex Benelux B.V.
Please note!
The minimum chimney diameter for a
130mm flexible stainless steel pipe must
be 200x200mm and for a 100mm flexible
stainless steel pipe and 150x150mm.
Don’t connect more than one fire at the
existing chimney.
The chimney must be in good condition:
o
No leakage;
o
Well cleaned.
For more information about the connections to
existing chimney ducts, please request the
installation instructions “Chimney Connection Set”.
4
Preparation and installation
instructions
4.1
Gas connection
The gas connection must comply with the
applicable local standards.
Please note!
Provide a flexible gas connection with at
least 0,5m extra length, so that the
control unit can be removed for
installation and service!
Calculate the gas pipe so that no
pressure drop occurs.
We advise using a gas connection directly from the
gas meter to the appliance, with a shut-off valve in
Summary of Contents for MatriX 800/500 RD H
Page 2: ...Installation manual MatriX 800 1050x500 RD ST H 1...
Page 3: ...Installation manual MatriX 800 1050x500 RD ST H 2...
Page 4: ...Installation manual MatriX 800 1050x500 RD ST H 3 1 0 1 1 1 2 1 3 1 4...
Page 6: ...Installation manual MatriX 800 1050x500 RD ST H 5 2 1a 2 1b 3 0a 3 0b 3 1a 3 1b 4 0 4 1...
Page 7: ...Installation manual MatriX 800 1050x500 RD ST H 6 4 2 4 3 4 4 4 5 4 6 4 7 4 8 4 9...
Page 8: ...Installation manual MatriX 800 1050x500 RD ST H 7 5 0 6 0 6 1...
Page 19: ...Installation manual MatriX 800 1050x500 RD ST H 18 12 Examples flue materials...
Page 23: ...Installation manual MatriX 800 1050x500 RD ST H 22 14 2 MatriX 1050 500 RD H ST H...
Page 30: ...Installation manual MatriX 800 1050x500 RD ST H 29 18 3 Control box FAB1806...
Page 33: ...Installation manual MatriX 800 1050x500 RD ST H 32...
Page 34: ...Installation manual MatriX 800 1050x500 RD ST H 33...
Page 35: ...Installation manual MatriX 800 1050x500 RD ST H 34...