Installation manual MatriX 1050/500 I,II,III 2 and MatriX 1050/650 I,II,III 2
23 <
<
<
<
Search in the table at TVH and THL and enter the value that is found.
found value
………………………………
If the detected value is a number, check whether the completed STL is higher or equal to the value in
the table.
Is the STL value lower as specified in the table then the installation is not possible.
Solution: Start length to low, see for the minimum length in the top row of the table.
Is the found value X, then the installation is not possible.
Solution: Change the TVH or THL.
Results
Restrictor size = Value for the comma
………………….. mm
Extra information = Value behind the comma
mark
Install the air restrictor plate, see installation manual
0,1
Install adapter 100/150 direct on top of the fire
0,2
In case of wall terminal, install adapter 100/150 before
the last bend, in case of roof terminal just before the
terminal.
0,3
In case of roof terminal (always size 100/150) install the
100/150 adapter just before the terminal.
Wall terminal 130/200
0,4
From the fire first an adjuster to 130/200 and 1 meter
130/200, after that reduce to 100/150 and everything
100/150.
0,5
Summary of Contents for MatriX 1050/500 II
Page 1: ...Installation manual MatriX 1050 500 I II III 2 MatriX 1050 650 I II III 2 ENG 40012103 2220...
Page 2: ...Installation manual MatriX 1050 500 I II III 2 and MatriX 1050 650 I II III 2 2...
Page 3: ...Installation manual MatriX 1050 500 I II III 2 and MatriX 1050 650 I II III 2 3...
Page 41: ...Installation manual MatriX 1050 500 I II III 2 and MatriX 1050 650 I II III 2 41 17 4 17 5...
Page 42: ...Installation manual MatriX 1050 500 I II III 2 and MatriX 1050 650 I II III 2 42...
Page 43: ...Installation manual MatriX 1050 500 I II III 2 and MatriX 1050 650 I II III 2 43...