Installation manual MatriX 1050/500 I,II,III 2 and MatriX 1050/650 I,II,III 2
22 <
<
<
<
13
Calculation sheet
Starter length (STL)
First part on top of the appliance
Value
Value
Flue length from 0,1m till 0,45m
0,2
Flue length from 0,5m till 0,90m
0,5
Flue length from 1m till 1,4m
1
Flue length from 1,5m till 2m
1,5
Flue length 2m or more
2
Bend 90°
0,1
Bend 45°, 30° or 15°
0,2
Roof terminal
1
Wall terminal
0
……………………..
Total Vertical Height (TVH)
measured height
rounded value
…………………………………………………… meter
……………. meter
Total Horizontal Length (THL)
Calculation
Part
number
x
value
result
rounded value
Total Length in meters
………
x
1
……………..
90° Bend, vertical to
horizontal
………
x
0,4
……………..
45° Bend, vertical to
horizontal
………
x
0,2
……………..
90° Bend in horizontal
direction
………
x
1,5
……………..
45° Bend in horizontal
direction
………
x
1
……………..
flue pipes at an angle in
meters
………
x
0,7
……………..
Total
……………+
………………….. meter