The Inca Smart requires 5" round ductwork.  To ensure that the blower performs to its 

highest possible capacity, ductwork should be as short and straight as possilbe.

Make your ductrun as straight and short as possible.  The ductrun should not exceed 25 

equivalent feet if ducted with the required minimum of 5" round duct.  Count 45º angles 

as 3 feet, 90º elbows as 5 feet, and 90º flat elbows as 12 feet.

For best results, use no more than three 90°  elbows.  Make sure that there is a 

minimum 

of 24" of straight duct between elbows if more than one is used.  

Do not install two 

elbows together.  

If you must elbow right away, do it as 

far away

 from the hood's 

exhaust opening as possible.

TOOLS  NEEDED  FOR  INSTALLATION

• Saber Saw or Jig Saw 

• Drill 

• 1  1/4" Wood Drill Bit 

• Pliers

• Phillips Screwdriver

• Wire Stripper or Utility Knife

• Metal Snips

• Measuring Tape or Ruler 

• Level

• Pencil

• Caulking Gun

• Duct Tape 

PLAN YOUR DUCTWORK 

The  Inca  Smart  can  be  used  in 

standard 30" or 36" wide cabinetry 

or  with  custom  hoods  30"  wide 

and up.

  

For  custom/wood  hoods,  choose 

either a custom liner or our Standard 

Liner  designed  for  30"  and  36" 

wide installations.  Liners create a 

perfectly-sealed, non-combustible 

finish  for  the  underside  of  your 

custom/wood hood.

The  Standard  Liners  are  made 

up of two sections: a larger, rear 

section (pre-cut out for insertion of 

the Inca Smart) and a front section 

for a total adjustable depth between 

16" and 17 

7/8"

.

!!! IMPORTANT NOTE: 

DO NOT 

REMOVE  THE  ADDITIONAL 

P E R F O R AT E D   S E C T I O N 

AROUND  THE  PRE-CUT-

OUT  WHEN  INSTALLING 

THE  STANDARD  LINER  WITH 

THE  INCA  SMART  MODEL.  

THIS  PERFORATION  IS  ONLY 

REMOVED FOR USE WITH THE 

INCA HC SS MODEL.

Consider  the  shape,  size,  and 

weight of the Inca Smart and Liner 

to  determine  the  configuration 

of  the  custom/wood  hood.    See 

RANGEHOOD DIMENSIONS AND 

LINER DIMENSIONS

 on Page 4.

FOR INSTALLATIONS WITH LINERS

PARTS  SUPPLIED  FOR  INSTALLATION 

• 1 Backdraft Damper

• 10 Screws

• Field Wiring Box

• 1 Literature Package

PARTS  NEEDED  FOR  INSTALLATION

• 2 Conduit Connectors

• Power Supply Cable

• Scews for Field Wiring Box

• 1 Wall or Roof Cap

• All Metal Ductwork

OPTIONAL ACCESSORIES AVAILABLE

• 

Charcoal Filter Kit

For recirculating installations only,

replace charcoal filters as needed

part # 6093130

• 

Liners

Create  a  perfectly-sealed,  non-combustible 

perimeter around the Inca Smart.  Depth adjustable 

from 16" - 17 

7/8"

.

Standard Liner 30 Stainless - part # 620000304

Standard Liner 36 Stainless - part # 620000305

CUSTOM/WOOD

HOOD

STANDARD LINER

INCA SMART

   

WARNING

!

When building a custom hood, 

always  follow  all  applicable 

codes and standards.

1. 

The custom/wood hood must have a sturdy base (3/4" plywood recommended) to accomodate 

the cut-out for the Inca Smart.  The base must be recessed to accomodate the height of the 

Liner (see 

LINER DIMENSIONS

 on Page 4).  The Liner attaches to the bottom of the base 

using  screws appropriate for the size and material of your custom/wood hood. The Inca Smart 

inserts into the cut-out in the Liner and base.

2. 

Position the rear section of the Liner so that it abuts the back edge of your custom/wood 

hood.  Using a pen, trace the outline of the pre-cut out.  Remove the Liner and proceed to 

MAKE 

YOUR CUT-OUTS

 on Page 6.  Install both sections of the Liner and proceed to I

NSTALL THE 

RANGEHOOD

 on Page 6.

Summary of Contents for INCA SMART

Page 1: ...RMINIMISERLERISQUED UNFEUDEGRAISSESURLATABLEDECUISSON a Nejamaislaisser un l ment de la table de cuisson fonctionner sans surveillance la puissance de chauffage maximale un renversement d bordement de...

Page 2: ...is not recommended DO NOT obstruct the ow of combustion and ventilation air Failure to follow venting requirements may result in a re When making the electrical connection cut a 1 1 4 hole in the wall...

Page 3: ...tion est n cessaire pour tous les appareils combustion Suivez les conseils et mesuresdes curit dufournisseurtelsqueceuxpubli s par l Association Nationale de la Sauvegarde contre l Incendie et l Assoc...

Page 4: ...itional perforated section Note Les Cadres Standard sont pr coup s pour l installation de l Inca Smart Pour des installations avec L Inca HC SS enlevez la section perfor e additionnelle RANGEHOOD DIME...

Page 5: ...WHEN INSTALLING THE STANDARD LINER WITH THE INCA SMART MODEL THIS PERFORATION IS ONLY REMOVED FOR USE WITH THE INCA HC SS MODEL Consider the shape size and weight of the Inca Smart and Liner to deter...

Page 6: ...ated on either side 4 Fix the rangehood to the cabinet using the two spring loaded brackets one on each side of the rangehood B in FIGURE 4 Using a philips screwdriver tighten theadjustmentscrew CinFI...

Page 7: ...of each control button is indicated in FIGURE 5 FIGURE 5 281_06 Clean exterior surfaces with hot soapy water Abrasives and scouring agents can scratch rangehood nishes and should not be used to clean...

Page 8: ...FORATIONESTSEULEMENT ENLEV E POUR L USAGE AVEC LE MOD LE DE L INCA HC SS INSTALLATIONS AVEC CADRES PI CES FOURNIES POUR L INSTALLATION 1 registre clapet 10 vis Compartiment de lage 1 n cessaire de doc...

Page 9: ...s l ouverture d chappement de la hotte et appuyer forte ment sur le registre 3 Retirer le bas de la hotte en tirant sur les pattes grises A de la FIGURE 3 qui se trouvent sur les deux c t s 4 Installe...

Page 10: ...sson et les odeurs de la cuisine Panneau de commandes Le panneau de commandes est situ sur le c t La position et la fonction de chaque bouton sont indiqu es la FIGURE 5 281_06 FIGURE 6 FIGURE 7 DIAGRA...

Reviews: