Appendix B: Flue restrictor
Determining of the right flue restrictor:
•
Calculate the total horizontal- and vertical length of the flue, according to the
calculations displayed above
•
Determine according to the table the right flue restrictor size
•
When meeting an X, and when the values are outside the table, the combination is
not allowed
•
Normally the 30 mm flue restrictor is preinstalled
Horizontal length (m)
Honest
0
1
2
3
4
5
6
0
X
X
X
X
X
X
X
0,5
X
0
X
X
X
X
X
1
30
30
0
0
0
0
X
1,5
30
30
30
0
0
0
0
2
40
40
30
30
0
0
0
3
40
40
40
30
30
0
0
4
50
40
40
40
30
30
0
5
50
40
40
30
30
30
0
6
50
50
40
40
30
30
0
7
60
50
50
40
40
40
X
8
60
50
50
40
40
X
X
9
65
60
50
50
X
X
X
10
65
60
60
X
X
X
X
11
65
65
X
X
X
X
X
Real vertical height (m)
12
65
X
X
X
X
X
X
Summary of Contents for Honest
Page 1: ...Honest Installationguide Sity Gas 40010739 0902 ...
Page 3: ... 2 Placing the log set 2 1 2 2 2 3 2 4 ...
Page 4: ...3 L L Placing the glass 3 1 3 2 3 3 3 4 3 5 3 6 ...
Page 19: ... 18 Appendix F Dimensions ...
Page 20: ...19 L L Appendix G Ventilation Grid ...
Page 21: ... 20 Appendix H Service Hatch ...
Page 22: ......
Page 23: ... 2 ...