Installation manual e-MatriX mood 800/500 I,II,III and e-MatriX mood 800/650I,II,III
12 <
<
<
<
Removing glass
5.1
Front glass
e-MatriX I:
Remove the cover list, see fig. 2.0a.
Rotate both glass clamps clockwise, see
fig. 2.0b.
Place suction cups and remove the front
glass see fig. 2.0c.
For replacing the glass repeat the steps in reverse
order.
e-MatriX II and e-MatriX III:
Rotate both glass clamps clockwise, see
fig. 2.1a.
Place suction cups and remove the front
glass, see fig. 2.1b or 2.1c.
For replacing the glass repeat the steps in reverse
order.
5.2
Side glass
For cleaning only it’s not necessary to remove the
side glass.
First remove the front glass, see chapter
5.1.
Place a suction cup and remove the side
glass, see fig. 2.2.
For replacing the glass repeat the steps in reverse
order.
Decoration set
Please note!
To get the right glow effect, the (optional) bot-
tom lighting must be switched on at 100% in-
tensity.
Make sure the ITC-V2 App is connected to the fire,
see fig. 7.0.
Switch on the glow effect, see fig. 7.1.
Click on the “flame” in the circle, see fig.
7.1.
Click on the “settings”, see fig. 7.2.
Set “bottom lighting” to maximum, see
fig. 7.3.
6.1
Log set
See the included decoration instruction card or
Chapter 11:
Please note!
Placing the logs is a meticulous job, this deter-
mines the flame distribution.
Do not let any decoration material fall into
the outflow (fire) opening.
The outflow openings may not be completely
covered.
Divide the mini chips over the bottom;
Place the wooden logs;
Apply the ash material.
Fine tuning of the glow bed
By placing the decoration chips close together you
create a real glow bed.
6.2
Pebbles/Acrylic ice
Spread an even amount of Pebbles or Acrylic-ice on
the bottom plate.
Functional test
See “Using the appliance for the first
time” in chapter 4 of the user manual.
Check all connections for water leaks.
Check the operation of the extractor fan.
Check the operation of the heating fan.
Check the operation of the remote control
at the desired distance (max. 8m).
Check the operation of the ITC-V2 App.
Place the decoration set, see chapter 6.
Place the front glass, see chapter 5.1.
Do a final functional test.
Maintenance
8.1
Maintenance frequency
Cleaning water sump, air filter and replac-
ing the transducer.
Commercial use:
o
Every three months.
Domestic use:
o
Once a year.
Cleaning mesh filter and replacing in-line
filter.
Commercial use:
o
Once a year.
Domestic use:
o
Every second year.
Please note!
The maintenance interval depends on the wa-
ter quality and/or the running hours and