Installation manual e-MatriX mood 800/500 I,II,III and e-MatriX mood 800/650I,II,III
10 <
<
<
<
Hanging on the wall (fig. 1.2)
The fire can be mounted on the wall using the op-
tional wall bracket “A” (see also dimensional draw-
ing in chapter 10.6). Remove the brackets (on top
of the appliance) and mount them on both sides.
Now they can be used to level the appliance verti-
cally.
4.3
Installation and finishing
See fig. 1.5 and fig. 1.6.
A = cover strip
B = built-in support
C = glass support
D = top of the slot (glass)
E = magnet (adjustable)
F = false chimney breast
G = plateau
With cover strip (fig. 1.5)
e-MatriX I:
Build the false chimney breast against cover strip A
and built-in support B.
e-MatriX II and III:
Don’t build the false chimney breast (incl.
cover strip) higher than point D.
Adjust the magnets 6mm lower than point
D.
Without cover strip (fig. 1.6)
Please note!
At the e-MatriX front glass only versions, the
cover strip is fixed by screws, remove those
first, see fig. 1.3.
Remove built-in support B from the fire. Build the
false chimney breast against glass support C.
4.4
Control box (see fig. 1.0)
Please note!
Fix the Control box at an accessible location
behind the service door, see dimensional
drawing 10.5 and 10.7.
Connection of the control box to the e-MatriX,
see fig. 1.0:
A = control cable, 9 pole
B = power cord (power supply Control box)
C = extension cable (power supply Control
box to Engine)
D = main switch on/off
E = external water pump connection
(optional)
Electrical connection
Please note!
Connect all plugs according to the diagram,
see fig. 3.0.
AA = control box
BB = Engine
CC = printed circuit board
DD = top lighting (optional)
EE = bottom lighting (optional)
FF = power supply LED
GG = fan extraction
HH = fan heating
II = external water pump (optional)
Lead control cable A, from the Engine to
the Control box and connect it, see fig.
1.0-A.
Connect the supplied extension cable B to
the Control box, see fig. 1.0-B.
(Max. cable length from the center of the
fire to the left is 1,5m.
Max. cable length from the center of the
fire to the right is 1,0m).
Connect the supplied power cord C to the
Control box, see fig. 1.0-C.
If desired, a 2m extension set is available (The ex-
isting cables are extended by 2m), item number
20901578.
Water connection
Please note!
Connect all parts according to the flow dia-
gram. See fig. 5.0.
Place the water filters, in the correct direction
of flow, in an accessible location. There is a
“flow direction” mark on both filters.
Water inlet
Connect the water supply pipe to the (inlet) water
connection of the control box (see dimensional
drawing 10.5).
Water supply to the Engine
Connect the blue flexible pipe, which protrudes
from the side of the fireplace, to the (outlet) wa-
ter connection on the control box (see dimension
drawing 10.5).
Assemble the flexible water pipe
Press the blue flexible pipes 15mm in a coupling
piece. When mounting correctly, you feel re-
sistance that you have to push through.