background image

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

www.faberfires.com

 

[email protected] 

Saturnus 8   

 

NL 8448 CC Heerenveen 

Postbus 219 

 

NL 8440 AE Heerenveen 

Summary of Contents for e-MatriX 800-500 RD

Page 1: ...Installation manual MatriX 800 500 RD MatriX 800 500 ST ENG 40011710 2002 ...

Page 2: ...Installation manual MatriX 800 500 RD ST 1 1 0 1 1 1 2 1 3 ...

Page 3: ...Installation manual MatriX 800 500 RD ST 2 1 4 1 5 ...

Page 4: ...Installation manual MatriX 800 500 RD ST 3 1 6 2 0 2 1a 2 1b 3 0a 3 0b ...

Page 5: ...Installation manual MatriX 800 500 RD ST 4 3 1a 3 1b 4 0a 4 0b 4 0c 4 0d ...

Page 6: ...Installation manual MatriX 800 500 RD ST 5 4 1a 4 1b 4 2a 4 2b 4 2c 4 2d ...

Page 7: ...lease note It is advisable to always install a screen for the fire place if children elderly or disabled people are present in the same room as the fireplace If regu larly vulnerable persons can be present in the room without supervision sufficient protection must always be placed around the fireplace This appliance must be installed according with the rules in force and used only in a sufficientl...

Page 8: ...arantee proper perfor mance The distance to combustible materials must be min 50mm calculated from out side of the flue material EN 1856 1 T600 N1 D Vm L20040 O 50 Outlets fig 1 6 The balanced flue pipe for combined air supply and discharge can use a wall terminal or a roof termi nal Verify that the desired outlet meets the local regulations regarding pollution and ventilation openings Please note...

Page 9: ... C in fig 1 0 and 1 2 Rough height adjustment With the adjustable optional legs Accurate height adjustment With the adjustable feet 4 6 Installing the flue pipes Install the flue pipes according to the installation manual supplied with the appliance The distance to combustible materials must be min 50mm calculated from the outside of the flue pipe Never start immediately with length ad justable co...

Page 10: ...height of the platform observe point K Fig 3 1b Due to the expansion of the fireplace there should be at least 2mm play be tween the platform and the glass supports J Fig 3 1b 5 Removing the glass 5 1 MatriX 800 500 RD Removing the glass from the front Remove cover strip A Fig 4 0a Rotate clamp B clockwise fig 4 0b Place the suction cups on the glass and slide the upper frame C upward fig 4 0c See...

Page 11: ...eck again that both burners ignition and ionisa tion pins are free of glass granules and chips Start the fireplace as described in the user manual Assess whether the flame distribution and if any the Symbio effect glow bed is good Move or remove any chips glass granules to create a nice glow bed Install the front glass and check the fire image 7 Checking the installation Checking for gas leaks Che...

Page 12: ... of o the appliance o the remote control o the App and its settings Give advice and instructions on care and cleaning of the glass Emphasize the danger of fingerprint burns at the glass Handover to customer o installation manual o user manual o decoration instruction card o suction cups o sample Faber glass polish 9 Annual maintenance Check Check and clean if necessary the combustion chamber the b...

Page 13: ...d pipes entirely in the horizontal plane See elbows I K and Q and the elements H J L M P and R fig 12 1 and 12 2 Horizontal length The Horizontal Length consists of the ele ments H J L M P and R fig 12 1 and 12 2 Elbows 90 in the horizontal plane Horizontal elbows are elbows entirely in the horizontal plane fig 12 1 12 2 and 12 3 I K and Q Elbows 45 or 30 in the horizontal plane Horizontal elbows ...

Page 14: ... 8 55 2 x x x x x x x x x x 9 55 2 x x x x x x x x x x 10 60 2 x x x x x x x x x x 11 60 2 x x x x x x x x x x 12 60 2 x x x x x x x x x x 13 70 2 x x x x x x x x x x 14 70 2 x x x x x x x x x x 15 70 2 x x x x x x x x x x 16 70 2 x x x x x x x x x x 17 80 2 x x x x x x x x x x 18 80 2 x x x x x x x x x x 19 80 2 x x x x x x x x x x 20 80 2 x x x x x x x x x x 21 80 2 x x x x x x x x x x 22 80 2 x...

Page 15: ... 75 40 75 40 70 40 60 40 50 40 30 40 x x 12 80 40 80 40 80 40 80 40 75 40 75 40 70 40 60 40 50 40 x x 13 80 40 80 40 80 40 80 40 80 40 75 40 75 40 70 40 60 40 x x 14 80 40 80 40 80 40 80 40 80 40 80 40 75 40 75 40 70 40 x x 15 80 40 80 40 80 40 80 40 80 40 80 40 80 40 75 40 75 40 x x 16 80 40 80 40 80 40 80 40 80 40 80 40 80 40 80 40 75 40 x x 17 80 40 80 40 80 40 80 40 80 40 80 40 80 40 80 40 80 ...

Page 16: ...Installation manual MatriX 800 500 RD ST 15 12 Examples flue materials ...

Page 17: ...l direction x 1 5 45 Bend in horizontal direction x 1 flue pipes at an angle in meters x 0 7 meter Calculation Total rounded value Total Vertical Height TVH measured height meter Total Horizontal Length THL Value Starter length STL First part on top of the appliance Flue length from 0 1m till 0 45m Flue length from 0 5m till 0 90m Flue length from 1m till 1 4m Flue length from 1 5m till 2m Flue le...

Page 18: ... fire first an adjuster to 130 200 and 1 meter 130 200 after that reduce to 100 150 and everything 100 150 0 5 Restrictor size Value for the comma Extra information Value behind the comma Search in the table at TVH and THL and enter the value that is found If the detected value is a number check whether the completed STL is higher or equal to the value in the table Is the STL value lower as specif...

Page 19: ...gy efficiency index EEI 84 84 Type heating output control room temperature no no no no no yes Glen Dimplex Benelux Saturnus 8 Heerenveen The Netherlands With mechanical control of the room temperature by thermostat Control of room temperature with open window detection yes With electronic control of the room temperature With electronic control of the room temperature plus day time switch With opti...

Page 20: ...osition outlet Distance mm D Under a gutter 500 E Under a roof edge 500 F Under a carport or balcony 500 G Vertical downpipe 300 H Inside and outside corners 500 J From wall surface to a wall outlet 1000 K Two gable outlets against over each other 1000 L Distance between two roof outlets 450 M Two roof outlets above each other on a pitched roof 1000 N Two gable outlets next to each other 1000 Shor...

Page 21: ...Installation manual MatriX 800 500 RD ST 20 16 Dimensional drawings 16 1 MatriX 800 500 RD ...

Page 22: ...Installation manual MatriX 800 500 RD ST 21 16 2 MatriX 800 500 ST ...

Page 23: ...Installation manual MatriX 800 500 RD ST 22 16 3 Control box FAB1806 ...

Page 24: ...Installation manual MatriX 800 500 RD ST 23 16 4 Ventilation grid article number A9296400 ...

Page 25: ...Installation manual MatriX 800 500 RD ST 24 16 5 Adjustable feet article number A9319696 ...

Page 26: ...Installation manual MatriX 800 500 RD ST 25 17 Decoration instruction card 17 0 17 1 17 2a 17 2b 17 2c ...

Page 27: ...Installation manual MatriX 800 500 RD ST 26 17 2d 17 2e 17 3 17 4 17 5 ...

Page 28: ...Installation manual MatriX 800 500 RD ST 27 ...

Page 29: ...Installation manual MatriX 800 500 RD ST 28 ...

Page 30: ...Installation manual MatriX 800 500 RD ST 29 ...

Page 31: ...Installation manual MatriX 800 500 RD ST 30 ...

Page 32: ...www faberfires com contact faberfires com Saturnus 8 NL 8448 CC Heerenveen Postbus 219 NL 8440 AE Heerenveen ...

Reviews: