UK/IRL
28
<
<
<
<
•
The existing chimney needs to be clean and very well swept;
•
The existing chimney needs to be airtight;
•
The existing chimney needs to have an opening of min. 150 x 150 mm.
Parts needed for this kind of installation:
•
Chimney connection set part number
A9225000 Fig 20 part D.
•
Short roof terminal part number
A9266100 Fig 19 part B
•
Chimney closure plate part number A
9240000 Fig 19 part A
•
Two stainless steel tubes one 100 mm -
length 500 mm and one 150 mm - length
500 mm part number A 9273900 Fig 19
part E and F
Installation:
1)
Place the aluminium closure plate (A)
onto the chimney. Permanently attach
and make airtight.
2)
Pull the liner (C) through the chimney.
3)
Connect the liner onto the roof terminal
and fix this with the clamp provided with
the chimney connection set.
4)
Place the roof terminal onto the closure
plate.
5)
Fixing the chimney sealing plate (D) and
place the 150 mm grommet into the hole
of the sealing plate.
6)
Fix the sealing plate air tight into the builders opening (use isolation
rope from the chimney connection set to make the plate air tight).
7)
Slide pipe (E) 150mm length 500mm into the sealing plate. Slide this
pipe so that you have enough space later on to assemble the liner.
Fig. 18