![Faber BREVA PRO 11 Installation Instructions Manual Download Page 27](http://html1.mh-extra.com/html/faber/breva-pro-11/breva-pro-11_installation-instructions-manual_3296822027.webp)
27
E - INTENSIVE LEVEL 1 -
A quick press will
operate intensive speed level 1 for 6 minutes.
INTENSIVE LEVEL 2 -
A 2 - second press
will
operate intensive speed level 2 for 6 minutes.
At the end of the 6 minutes the hood returns
to the speed that was set before. If intensive
is set with the motor turned off, the hood will
turn off after 6 minutes.
BUTTON
FUNCTION
INDICATOR
Grease Filter Alarm
- If the speed two and
intensive buttons are lit, this means the
Grease Filter saturation alarm is activated
and the grease filters should be washed. The
alarm turns on after 100 hours of operation.
Charcoal Filter Alarm -
if the alarm is
activated, the speed two and intensive lights
will blink. This means the Charcoal filters
should be replaced AND the grease filters
should be washed. The charcoal filter alarm
turns on after 200 hours of operation.
Heat Sensor Information -
The hood is equipped with a
temperature sensor which, if the motor is off and the temperature
below the stove is high, activates the motor at maximum speed.
The condition is indicated by the blinking of Speed 1 and 2 LED’s
, Speed 3 LED is lit. This condition persists until the temperature
returns below the threshold. It is possible to exit this mode by
selecting one of the speeds.
Summary of Contents for BREVA PRO 11
Page 6: ...6 RANGE HOOD DIMENSIONS 36 30...
Page 12: ...12 VENTING METHOD REAR OR TOP VENTED Horizontal Vertical 8 8 Rear 8 Go to Pg 13 Go to Pg 14...
Page 13: ...13 MOUNT THE DAMPER INTO THE HOOD 1 Attach the Damper E with 4 screws G Top position...
Page 16: ...16 IMPORTANT Attach the 4 previously removed screws to lock the motor in rear place 5...