UK/IRL
>
>
>
>
39
8.1.3 Burner tray (dis)assembly
1.
Break the gas supply at the control valve;
2.
Remove the glass, the log set, grid and burner tray cover;
3.
Detach the gas connection at the 8 mm nut and olive;
4.
Unscrew the burner assembly and take them out of the combustion chamber.
8.1.4 Gas control block
1.
Unscrew and remove the pilot system from its support and the burner plate;
2.
Disconnect the ignition/spark cabel;
3.
Disconnect the thermocouple from the pilot system;
4.
Disconnect the gas connection from the pilot system. Mind the injector: it’s unattached;
5.
The pilot system can now be removed;
6.
To assemble the pilot system again, follow the steps above in reversed order.
8.2 Propane conversion
For conversion from propane to natural gas, you have to order a complete new propane
burner unit. Contact your supplier and give the serial number from the data plate.
8.3 Combustion test
A BS7967 combustion analysis check should be carried out using an analyser to
BS7927 positioned in the flue outlet.
Ratio CO/CO2 should be less than 0.01 within 30 minutes (100 ppm CO per 1% CO2).
A reading of CO in the room centre should give a rise of less than 9ppm over ambient,
peak reading.
A. Governor
B. Adjusting
screw
pilot
flame
C.
Inlet pressure test point
D. Burner
pressure
test
point
Summary of Contents for BF110V/Straight
Page 2: ...UK IRL 2 ...
Page 11: ...UK IRL 11 BF110V Straight Frameless Top view false chimney breast Top view of the appliance ...
Page 12: ...UK IRL 12 Front view false chimney breast BF110V Straight Frameless ...
Page 13: ...UK IRL 13 BF110V Straight With frame Top View Front View ...
Page 15: ...UK IRL 15 Top View Front View Front View Cross section side BF120H Relaxed With frame ...
Page 16: ...UK IRL 16 Operation door ...
Page 41: ...UK IRL 41 User guide ...
Page 42: ...UK IRL 42 ...