4.3 Installing the appliance with the Faber false chimney breast
When the appliance is purchased with a Faber false chimney breast, then first follow the
instructions delivered with the package of the false chimney breast.
4.4 Installing the appliance in an existing or different false chimney
breast.
Read the requirements described in paragraph 3.1 before continuing with the installation!
4.4.1 Preparing the surround
1.
Check if the floor and wall are sufficiently level. If necessary, improve it;
2.
If the floor will be raised higher (e.g. by installing carpet or parquet), the floor
underneath the fire place has to be equally raised;
3.
Insulate the back wall with promatec of comparable inflammable material;
4.
Drill holes for the flue routing. Minimum height with flue routing through the back wall
is the height of the appliance plus the pipe bend. When going through the roof, a hole
with a diameter
∅
200mm has to be drilled in the ceiling at a distance of 170 mm from
the wall to the heart of the hole. This hole
indicates the centre of the false chimney
breast. Moving it afterwards is not possible.
5.
Adjust the floor plate, if necessary:
•
Drill a hole on the floor plate where
the gas connection will come out of
the floor;
•
Cut off the knockouts (A en B, see
figure) which are meant for the Faber
false chimney breast;
6.
Position the floor plate and mount it to the
floor;
7.
Prepare the gas connection, see paragraph
4.1.
Summary of Contents for BF110V/Straight
Page 2: ...UK IRL 2 ...
Page 11: ...UK IRL 11 BF110V Straight Frameless Top view false chimney breast Top view of the appliance ...
Page 12: ...UK IRL 12 Front view false chimney breast BF110V Straight Frameless ...
Page 13: ...UK IRL 13 BF110V Straight With frame Top View Front View ...
Page 15: ...UK IRL 15 Top View Front View Front View Cross section side BF120H Relaxed With frame ...
Page 16: ...UK IRL 16 Operation door ...
Page 41: ...UK IRL 41 User guide ...
Page 42: ...UK IRL 42 ...