Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible pipe ø120 mm.
• Insert the reducer flange
9
on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove possible charcoal filters.
ø 150
9
ø 120
RECIRCULATION VERSION AIR OUTLET
• Cut a hole ø 125 mm in any shelf that may be positioned over
the hood.
• Insert the reducer flange
9
on the hood body outlet.
• Connect the flange to the outlet on the shelf over the hood by
using a flexible or rigid pipe ø120 mm.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Fix the air outlet grid
8
on the recirculation air outlet by using
the 2 screws
12e
(2,9 x 9,5) provided.
• Ensure that the activated charcoal filters have been inserted.
9
ø 125
8
12e
ELECTRICAL CONNECTION
• Connect the hood to the mains through a two-pole switch hav-
ing a contact gap of at least 3 mm.
• Remove the grease filters (see paragraph Maintenance) being
sure that the connector of the feeding cable is correctly inserted
in the socket placed on the side of the fan.