background image

 

 

 

 

EN 

8

 

HOW TO FIX THE FINISH PANELS 

•  Pull the metal visor by rotating it forward, unlocking at the 

same time the lock which is fixed outside the hood. 

•  Lean the visor on the frontal finish panel, line it as you need if 

necessary, join the visor together to the eventual visor exten-
sion, by taking it between the panel and the visor before fixing 
all pieces with the supplied screws. 

•  Fix the lateral finish panels.

 

 

WALL FIXATION 

•  The hood depth can vary between 275 and 360 mm. 
•  Adap the Vx screw to the bracket to necessary depth. 
•  In order to adapt the lower part of the hood to the necessary 

depth, loosen the screws from the metal spacer and move it till 
necessary. 

•  Drill the wall as per drawing, apply the dowels in the holes and 

fix the metal. 

  Brackets with four Screws furnished with accessories. 
 
In case the hood is in Exhausting version, remove the grid on the 
air Duct 
 

•  Fix the Hood to the metal bracket. 
•  Reassemble the visor by carefully inserting the tracks in their 

places. Regulate the visor sliding moving the screws 

•  Agendo sulle Viti 

Vy

 si potrà allineare la Cappa in altezza ris-

petto ai pensili vicini. 

• By adapting the 

Vy

 screws, you will regulate the height of the 

hood with regards to the furniture 

•  If necessary you can also regulate the Hood depth. 
 

•  Lean the security square above the fixing brackets

 

•  Mark the centre of the holes.

 

•  Drill wall and fix the security squares with furnished Screws 

and dowels. 

 

275-360 mm

Vx

Vy

Vx

Vy

Min.  530 mm

Max. 750 mm

639 (Mod. da 90cm)

539 (Mod. da 60cm)

80

207

Summary of Contents for 106/35 PLUS

Page 1: ...Instructions Manual Felhaszn l i K zik nyv...

Page 2: ...2 2 INDEX SAFETY INFORMATION 3 CHARACTERISTICS 6 INSTALLATION 7 USE 10 MAINTENANCE 11 T RGYMUTAT BIZTONS GI INFORM CI K 12 JELLEMZ K 15 FELSZEREL S 16 HASZN LAT 19 KARBANTART S 20 EN HU...

Page 3: ...eight please refer to the paragraphs on working dimensions and installation If the instructions for installation for the gas hob specify a greater distance this must be respected Check that the mains...

Page 4: ...to be adopted for fume discharging it is important to closely follow the regulations pro vided by the local authorities WARNING Before installing the Hood remove the protective films Use only screws a...

Page 5: ...ls not applicable to appliances that only discharge the air back into the room The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead i...

Page 6: ...Light Filters Suction Unit 8 1 Directional Grille 125 mm 9 1 Reduction Flange 150 120 mm Ref Q ty Installation Components 7 2 2 Hood Canopy Fixing Brackets 7 3 2 Safety Assembly Frames 11 6 Wall Plugs...

Page 7: ...EN 7 7 INSTALLATION Dimensions...

Page 8: ...ill necessary Drill the wall as per drawing apply the dowels in the holes and fix the metal Brackets with four Screws furnished with accessories In case the hood is in Exhausting version remove the gr...

Page 9: ...he hood body outlet Connect the flange to the outlet on the shelf over the hood by using a flexible or rigid pipe 120 mm Fix the pipe in position using sufficient pipe clamps not sup plied Fix the air...

Page 10: ...xtraction capacity and the noise level it is suitable for most of the cooking conditions 3 Maximum speed suitable for the cooking conditions when vapours and smells are of the utmost emission even for...

Page 11: ...to dry before refitting When refitting the filters make sure that the handle is visible on the outside Activated charcoal filter Recirculation version These filters are not washable and cannot be rege...

Page 12: ...sok alacsonyabban is felszerelhet k l sd az zemi m retekre s az zembe helyez sre vonatkoz fejezetet Amennyiben a g zf z lap zembe helyez si tmutat ja a fentin l nagyobb t vols got r el gy azt kell bet...

Page 13: ...ontos a helyi hat s gok ltal el rt szab lyok szigor betart sa FIGYELMEZTET S az elsz v zembe helyez se el tt el kell t vol tani a v d f li kat Csak a k sz l khez megfelel t pus csavarokat s apr alkatr...

Page 14: ...k sz l kekkel egyidej leg haszn lj k olyan k sz l kek mellett sem haszn lhat amelyek kiz r lag a helyis gbe engedik a leveg t A term ken illetve a csomagol son l that szimb lum arra utal hogy a term...

Page 15: ...vil g t s sz r k sz v blokk 8 1 Ir ny tott r cs 125 mm tm 9 1 Sz k t perem 150 120 mm tm Hiv Db Felszerel si alkatr szek 7 2 2 K sz l kh zat r gz t kengyel 7 3 2 Biztons gi keret 11 6 Tiplik 12a 6 Cs...

Page 16: ...HU 1 16 FELSZEREL S Helysz ks glet...

Page 17: ...zd tsa el azt sz ks g szerint Az br nak megfelel en k sz tsen furatokat a falon tegye be azokba a tipliket majd r gz tse a k t f mkengyelt a tartoz kk nt adott csavarokkal Kivezet ses v ltozatk nt val...

Page 18: ...sz l kh z kimenet hez Egy 120 mm tm r j merev vagy rugalmas cs vel csatlakoz tassa a peremet a k sz l k f l tti konzolon lev kimeneti ny l shoz A cs r gz t s hez haszn ljon megfelel cs szor t p ntokat...

Page 19: ...ebess g ami az zemi k r lm nyek t bbs g hez aj nlott tekintettel a kezelt leveg mennyis ge s a zajszint k z tti kedvez ar nyra 3 Legnagyobb sebess g ami ak r hosszabb id tartamon kereszt l is alkalmas...

Page 20: ...a megsz radni a sz r ket gy szerelje ket vissza hogy a foganty a k ls l that r sz fel essen Akt v szenes szagsz r k keringet ses v ltozat Az akt v szenes szagsz r nem moshat s nem regener lhat hanem k...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...991 0537 882_ver2 181129 D00004559_01...

Reviews: