background image

2

The device contains IR and visible laser diodes.

IR laser: wavelength 905nm; max. output pulse power 75W 

(Class 1 according to IEC 60825-1)

Visible laser: wavelength 650nm; max. output CW power 3mW 

(Class 3R according to IEC 60825-1)

The visible laser beams are inactive during normal functioning.

The installer can activate the visible lasers if needed.

CAUTION!

 

Use of controls, adjustments or performance of procedures other than those specified herein 

may result in hazardous radiation exposure.

SAFETY

INSTALLATION AND MAINTENANCE

Avoid extreme

vibrations.

Do not cover 

the front screens.

Avoid moving objects 

and light sources in 

the detection field.

Avoid condensation.

Avoid the presence 

of smoke and fog in 

the detection field.

Avoid exposure to 

sudden and extreme 

temperature changes.

Keep the sensor 

permanently powered 

in environments where 

the temperature can 

descend below 0°C.

Wipe the front 

screens regularly 

with a clean and 

damp cloth.

Do not use aggressive 

products to clean 

the front screens.

Avoid direct exposure 

to high pressure 

cleaning.

Do not look into the laser 

emitter or the visible red 

laser beams.

The warranty is void if 

unauthorized repairs are 

made or attempted by 

unauthorized personnel. 

Only trained and qualified 

personnel may install and 

adjust the sensor. 

After installation, enter 

an access code by remote 

control.

This sensor is designed to be used as a movement and presence detector to control the opening and the closing 

process of a gate or a barrier. Other use of the device, especially on industrial doors, is outside the permitted purpose 

and cannot be guaranteed by the manufacturer and might infringe the following patent application EP 1 470 314 B1.

The manufacturer of the system is responsible for installing the sensor and the system in compliance with applicable 

national and international regulations and standards on safety and if applicable, the machinery directive 2006/42/EC.

The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of 

the sensor.

Summary of Contents for XGUARD-5H

Page 1: ...1 XGUARD 5H EN LASER SCANNER FOR BARRIERS GATES User s Guidefor product version 0100 and more with max detection range of 5 0 m x 6 5 m...

Page 2: ...n and damp cloth Do not use aggressive products to clean the front screens Avoid direct exposure to high pressure cleaning Do not look into the laser emitter or the visible red laser beams The warrant...

Page 3: ...osition lock 2 5 connector 6 protection cover 7 visible laser beam 3 8 notch for tilt angle adjustment 2 9 adjustable bracket 1 Detection LED relay 1 opening field 2 Detection LED relay 2 safety field...

Page 4: ...ontrol If the red LED flashes quickly after unlocking you need to enter an access code from 1 to 4 digits X NUMBER OF FLASHES VALUE OF THE PARAMETER field width 4 2 m field width is defined by teach i...

Page 5: ...order to avoid vibrations Close the protection cover and fasten it firmly Turn the sensor until the two triangles are face to face Position the housing on the bracket Open the protection cover plug th...

Page 6: ...e sequence After 15 minutes the beams switch off Verify the lateral position of the sensor Make sure the laser beam is visible on the opposite pole Verify if both beams are on equal height No test fun...

Page 7: ...NT surface of min 15 cm WITHOUT REFERENCE POINT left right The sensor will automatically adjust the safety field on the basis of the reference point if C 00 OR Choose the correct mounting side LEFT or...

Page 8: ...Once the sensor has finished the teach in make sure that the safety field is correctly configured and that the area around the barrier or gate is safe The safety field can be adapted more precisely b...

Page 9: ...ne If you walk along the detection area while the teach in function is active the sensor memorizes the outline of the walkpath and stores this as a new detection field The shortest distance measured b...

Page 10: ...hing and going away 400 CENTER unidirectional detection only approaching in any direction 200 CENTER unidirectional detection only approaching towards the barrier gate 100 CENTER unidirectional detect...

Page 11: ...ive P passive REMOTE CONTROL ADJUSTMENTS OPTIONAL DETECTION DELAY approximate values SAFETY FIELD REDIRECTION RELAY 1 RELAY 2 off presence presence presence motion motion or presence motion presence o...

Page 12: ...roximity to the sensor You have to enter an access code or the wrong code was entered The object size is too small Check the size of the fields Launch a teach in Step out of the field and or remove th...

Page 13: ...t screens Norm conformity laser scanner time of flight measurement motion and presence 5 0 m x 6 5 m 2 0 3516 wavelength 905 nm max output pulse power 75 W CLASS 1 wavelength 650 nm max output CW powe...

Page 14: ...14...

Page 15: ...15...

Page 16: ...PLEASE KEEP FOR FURTHER USE DESIGNED FOR COLOUR PRINTING BEA hereby declares that the XGUARD 5H is in conformity with the basic requirements and the other relevant provisions of the directives 2014 3...

Reviews: