![background image](http://html1.mh-extra.com/html/faac/tm2-x-r-compact/tm2-x-r-compact_manual_3122050024.webp)
TM2 X R MINI
24
A4518_6H82_Rev.A
SETTING THE FIRST REMOTE CONTROL
SETTING THE ROTATION DIRECTION OF THE MOTOR
This operation can only be performed when the control unit is new, or after a total
delete of the memory.
During this step, power up only one control unit at time!
T1: First remote control to be set
This operation is mandatory if the rotation direction of the motor does not match
to the UP and DOWN functions of the remote control as an exemple if giving up
command the awning or blinds descend.
The proper motor direction must be set, if the motor is linked to a Wind sensor. In
case of a wind alarm, the motor will always perform the command associated to
the UP button.
Setting the rotation direction using the SET button:
Interchanging the BROWN and BLACK motor wire on the terminals of the control
unit, will also reverse the rotation direction.
The control unit will keep this setting even after complete memory clearing.
max. 2 sec
Every time you connect the power supply to the control unit, you have 3 hours
to store the first remote control. After this time, the ability to store the remote
control is disabled. To reset the timer of the function you have to disconnect
and reconnect the power supply to the control unit.
AUTOMATIC DISABLING OF THE FIRST
REMOTE CONTROL SETTING FUNCTION
T1
T1
T1 (2 sec)
+
A
B
B
B
EN
Summary of Contents for TM2 X R COMPACT
Page 1: ...TM2 X R MINI...