950N 12 

732773 - Rev. B

ENGLISH

IT

ALIANO

• 

1 LANGUAGE (Diagram 2)

Selects the language in which the messages are displayed.

• 

2 SETUP (Diagram 3) -

• 

2.1 PARTIAL OPENING

Partial opening percentage

Selects  the  opening  percentage  (with  reference  to  total 

opening) obtained when in “Partial Opening” mode. 

Standard value: 80% 

Adjustment: from 60% to 100%

• 

2.2 PAUSE TIME 

Pause time value

Sets the pause time in automatic operating modes.

Standard value: 2 sec.

Adjustment: from 0 to 30 sec.

• 

2.3 NIGHT PAUSE TIME

Night pause time value

Sets the pause time in “night” operating mode. 

Standard value: 7 sec.

Adjustment: from 0 to 30 sec

.

• 

2.4 OBSTACLE DETECTION

Determines the behaviour of the automated system in case 

of repeated obstacle detection during the same operation.

Standard:

 The automated system attempts to complete 

the operation.

No Standard:

 Following the detection of an obstacle for 

three consecutive times, the automated system stops. Once 

the obstacle has been removed, the door must be closed 

manually to restore normal operation

• 

3 LOCK  (Diagram 4)

• 

3.1 LOCK KIT

On:

 Lock installed

Night:

 The electric lock locks the door only in “Night” mode.

One-Way+Night:

 The electric lock locks the door in “Night” 

and “One-way” mode.

Always:

 The electric lock locks the door every time it closes, 

regardless of the set operating mode.

Off:

 Lock not installed.

• 

4 DIAGNOSTICS  (Diagram 5)

• 

4.1 950

 

Shows the port hardware model and the software version 

of  the  950  MPS  and  950  I/O  boards  to  which  the  KP-

CONTROLLER is connected.

• 

4.2 Nr. of CYCLES

Shows the count (not resettable) of the cycles performed 

by the automated system.

• 

4.3 FAULT Nr.

Shows the number and description of the fault in progress. 

Refer to figure 3 for fault codes and descriptions.

• 

RESET

Performs  the  reset  procedure  and,  if  the  cause  of  the 

previously signalled fault has been eliminated, it restores 

normal operation.

• 

5 ADVANCED MENU

• 

PASSWORD

To access the advanced menu, the 4-digit password is 

required (default 0000).

• 

1 MOTION PARAMETERS  

(

Diagram 

6)

• 

1.1 CLOSING SPEED

Sets the door speed during closing. 

Standard value: level 8

Adjustment: from 0 to 10

• 

1.2  OPENING SPEED

Sets the door speed during opening. 

Standard value: level 8

Adjustment: from 0 to 10

• 

1.3  MAINTAIN SETTINGS

On: 

The automated system maintains the operating 

parameters set using the KP-CONTROLLER even if the 

latter is disconnected

Off:

 If the KP-CONTROLLER is disconnected, the opening 

and closing speed and the pause time must be set using 

the trimmers.

• 

2  IN/OUT SETUP  

(

Diagram 

7)

• 

2.1  EMERG 

Sets the effect of the emergency command 

(Emerg input on the 950 I/O board).

Standard setting: Opens/NC

Opens:

 Activating the command opens the door.

Closes: 

Activating the command closes the door.

No:

 Normally open input.

Nc:

 Normally closed input.

• 

2.2 OUT OP/CL

Sets operation of the 

Open

 and 

Closed

 status outputs of 

the 950 I/O board.

Standard setting: N.O.

Nc:

 Normally closed output.

No: 

Normally open output

• 

2.3 FAULT OUT 

Sets operation of the 

Fault

 status outputs of the 950 I/O 

board.

Standard setting: N.O.

No:

 Normally open output.

Nc

: Normally closed output.

• 

3   OTHER (Diagram 8)

• 

3.1  STANDARD SET UP

Makes it possible to verify if any non-standard programming 

has been performed.

Standard:

  If no standard programming function has been 

modified,  an  asterisk  will  be  displayed.  If  the  asterisk 

is not displayed, press “OK” to restore all the standard 

programming settings.

No Standard: 

If at least one standard programming function 

has been modified, an asterisk will be displayed.

• 

3.2  INTERLOCK

The  interlock  function  makes  it  possible  to  manage  two 

doors (master and slave) so that opening of one depends 

on the closing of the other and vice versa.

Off:

 Interlock not active

On:

 Interlock active.

7.1  DIAGRAM DESCRIPTION

Summary of Contents for KP CONTROLLER

Page 1: ...KP CONTROLLER q q OK ...

Page 2: ...LLER must be connected to the 950 I O board using a 2 x 0 5 mm2 max 50 m cable Fig 2 If the two LOCK terminals are connected to each other as shown in Fig 2 all programmer keys are inhibited 4 DIAGNOSTICS The KP CONTROLLER even without display features a diagnostic function which in case of fault interrupts every 2 sec normal visualisation of the operating mode and si gnals for 1 sec the fault con...

Page 3: ...d 10 Electric lock locked closed 12 No 24V accessories power 13 failsafe test failed on closing 14 failsafe test failed on opening 15 Set up prevented 18 Leaf stroke too long 20 Leaf stroke insufficient 22 Leaf too heavy 24 Motor failure 26 950 MPS board failure 28 Set up cycle requested 29 Encoder failure 30 Motor drive on 950 MPS board failure 31 EEPROM failure 32 Master and slave communication ...

Page 4: ...th the motor powered e NIGHT The door closes The internal and external radars are disabled The key control Key causes opening and closing after the night pause time standard 7 sec For partial opening in this mode before selecting Night mode activate Partial opening mode 6 SPECIAL FUNCTIONS 6 1 SET UP Set up is the door initialisation function during which parameter self learning is performed It is...

Page 5: ...setting parameters Use thep or q keys to select the submenu or parameter and OK to confirm An asterisk on the display indicates the currently active setting To exit programming select exit at each level as an alternative after approximately 2 minutes the display will automatically return to standard visualisation Following are the flow charts and notes describing the various menus and programming ...

Page 6: ...ING SETUP 80 PAUSE TIME 7 SEC EXIT 2 SEC OBSTACLE DETECTION CLOSING STANDARD CLOSING NO STANDARD ITALIANO ENGLISH DEUTSCH FRANCAIS ESPANOL LANGUAGE Diagram 2 Language selection The language choice can vary depending on the programming country Diagram 3 Setup ...

Page 7: ...950N 6 732773 Rev B ENGLISH Diagram 4 Lock OFF ALWAYS ONE WAY NIGHT NIGHT ON LOCK KIT LOCK EXIT Diagram 5 Diagnostics RESET DIAGNOSTICS 950 v NR of CYCLES XXXX FAULT nr fault description ...

Page 8: ... 0000 ADVANCED MENU PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 MOTION PARAMETERS CLOSING SPEED OPENING SPEED MAINTAIN SETTINGS OFF ON 8 8 EXIT IN OUT SETUP OTHER EXIT CHANGE PASSWORD incorrect code correct code Diagram 6 Motion parameters ...

Page 9: ...am 7 In Out Setup PASSWORD 0000 ADVANCED MENU PASSWORD 0000 PASSWORD 0000 PASSWORD 0000 incorrect code correct code MOTION PARAMETERS IN OUT SETUP OTHER EXIT CHANGE PASSWORD EMERG OPENS CLOSES OUT OP CL NO FAULT OUT NO NC EXIT NC NO NC ...

Page 10: ...ORD 0000 MOTION PARAMETERS IN OUT SETUP OTHER EXIT CHANGE PASSWORD STAND SETUP STANDARD NO STANDARD INTERLOCK MASTER SLAVE NO MEMORY WITH MEMORY EXIT NEW PASSWORD 0000 restore standard configuration MASTER SLAVE ON OFF ON OFF 2 LEAVES PROG TEST ON OFF NEW PASSWORD 0000 NEW PASSWORD 0000 NEW PASSWORD 0000 incorrect code correct code ...

Page 11: ... 00 SUN 00 00 00 00 00 CLOCK SUN 00 00 00 00 00 SUN 00 00 00 00 00 SUN 00 00 00 00 00 SUN 00 00 00 00 00 SUN 00 00 00 00 00 SUN 00 00 00 00 00 SUN 00 00 00 00 00 SUN 00 00 00 00 00 SUN 00 00 00 00 00 Diagram 9 Clock Diagram 10 Timer TIMER ON OFF ...

Page 12: ...D 2 FUN 0 00 00 TIME BAND 5 FUN 0 00 00 TIME BAND 4 FUN 0 00 00 TIME BAND 3 FUN 0 00 00 TIME BAND 1 FUN 0 00 00 TIME BAND 2 FUN 0 00 00 TIME BAND 5 FUN 0 00 00 TIME BAND 4 FUN 0 00 00 TIME BAND 3 FUN 0 00 00 TIME BAND 1 FUN 0 00 00 TIME BAND 2 FUN 0 00 00 TIME BAND 5 FUN 0 00 00 TIME BAND 4 FUN 0 00 00 TIME BAND 3 FUN 0 00 00 TIME BAND 1 FUN 0 00 00 TIME BAND 2 FUN 0 00 00 TIME BAND 5 FUN 0 00 00 ...

Page 13: ...d if the cause of the previously signalled fault has been eliminated it restores normal operation 5 ADVANCED MENU PASSWORD To access the advanced menu the 4 digit password is required default 0000 1 MOTION PARAMETERS Diagram 6 1 1 CLOSING SPEED Sets the door speed during closing Standard value level 8 Adjustment from 0 to 10 1 2 OPENING SPEED Sets the door speed during opening Standard value level...

Page 14: ...o NIGHT mode 8 PROGRAMMING TIMER Diagram 11 Makes it possible to create up to 5 different time bands for each day of the week setting the band start time and give each time band an operative function When the KP CONTROLLER internal clock reaches the start of a time band the associated operative function is automatically set and the door stays in that condition until the following time band is trig...

Page 15: ... of door 2 If interlock with memory is selected it is not necessary to wait for the door to be closed completely to activate the sensor on the second one 6 Door 2 opens 7 The person exits 8 Door 2 closes after the night pause time Operation is similar when coming from the opposite direction 8 1 2 INTERLOCK WITHOUT INTERNAL SENSORS buttons This application is recommended when the reduced distance b...

Page 16: ... automated systems causes immediate reversal of both The partial opening function makes it possible to control total opening only of the master The operating functions must be set only on the master automated system or on the KP Controller connected to it 1 Connect the 950I O board of the two automated systems as shown in fig 8 2 Connect all the sensors and pulse transmitters only to the master 3 ...

Page 17: ......

Page 18: ...6645 faactm info faacgroup com www faac de INDIA FAAC INDIA PVT LTD Noida Delhi India tel 91 120 3934100 4199 www faacindia com IRELAND NATIONAL AUTOMATION LIMITED Boyle Co Roscommon Ireland tel 353 071 9663893 www faac ie MIDDLE EAST FAAC MIDDLE EAST FZE Dubai Silicon Oasis free zone tel 971 4 372 4187 www faac ae NORDIC REGIONS FAAC NORDIC AB Perstorp Sweden tel 46 435 779500 www faac se POLAND ...

Reviews: