background image

 

 

 

Cellular Intercom 4G 

FAAC International Inc. 
Headquarter & East Coast Operations 
3160 Murrell Rd 
Rockledge, FL 32955 
Tel. 800 221 8278 
www.faacusa.com 

FAAC International Inc. 

West Coast Operations 

357 South Acacia Avenue 

Fullerton, CA 92831 

 

 

 

Preferred!

DO NOT GIVE TO HOME OWNER

.  

     FOR PROFESSIONAL USE ONLY       

Summary of Contents for FCI4400

Page 1: ...quarter East Coast Operations 3160 Murrell Rd Rockledge FL 32955 Tel 800 221 8278 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia Avenue Fullerton CA 92831 Preferred DO N...

Page 2: ...up and LEDS Installing the programmer APP for the first time Programming a brand new install Programming an existing install Programming main steps Additional Features Keypad codes Prox cards optional...

Page 3: ...ORE going to site Program the unit in the comfort of your work bench and call technical support should you have questions This product requires a SIM card from either At T or T Mobile however T Mobile...

Page 4: ...ll button Push button Speaker grill Cellular PCB Optional Prox Coil Optional Keypad module Optional Keypad Optional Prox reader module Surge Power Conditionin g Module Hinged front door Microphone Bui...

Page 5: ...seneck re fit the module and connect a 14 gauge earth wire to the earth terminal 2 Earth Rod close as possible Maintain manufacturer s warranty by adhering to the guidelines shown Use 110v surge prote...

Page 6: ...ds 3Ah 12v dc max Power Module in Detail Earth Rod Connection Gate Position Limit switch optional 1A quick blow input fuse Exit Button To Call Button 12v dc 100mA backlighting 24v dc IN pre wired CPU...

Page 7: ...Keypad PROX Modules in Detail Slave OUT connections Wiring Relays Electric Gates 24v out GND Note The manufacturer is not responsible for wiring to third party devices Please consult an experienced s...

Page 8: ...le power on Preferred To next device Optional Keypad Optional Prox reader Optional Slave Keypad Optional Slave Prox Reader CAT5 30ft max 300ft if device powered separately To next device 45 chamfer OU...

Page 9: ...Apple or Android smart phone download and install the FAAC Cell Access Pro APP It will make programming much easier Note You may notice the app Cell Access on the store This is for homeowners to use...

Page 10: ...10 Accept and allow all permissions Android version shown After you send the registration email go back to the app screen To register first time enter your name email and cell phone number...

Page 11: ...mming an EXISTING Install Enter site or customer name and INTERCOM PHONE NUMBER If Engineers and user pass codes are at default then do not change these Once completed you are ready to begin programmi...

Page 12: ...DIATE action Change network if possible or use an optional high gain antenna Check power cable is within recommended specification Poor power cable can lower reception SMS message sent to the intercom...

Page 13: ...n the intercom Step 3 Activate Daily Activity This feature is needed for 2 reasons 1 To prevent some cellular carriers disconnecting the 4G LTE due to inactivity on the device 2 To keep time synchroni...

Page 14: ...73telephonenumber To delete all numbers 9999 73 Step4 Programming Numbers for the intercom to call 1 Press the SINGLE home icon for a 1 button system or MULTI for a 10 button system 2 Simply enter ce...

Page 15: ...on E g 8 30am 0830 Enter end time in 24hr format military style with no colon E g 1 30pm 1330 Select the days which access are to be granted SMS string for time restricted caller ID 9999 72 day day da...

Page 16: ...tricted Code Stores up to 20 codes which can be restricted to pre set times and days of the week Relay 1 only Enter a 4 digit code Enter start time in 24hr format military style with no colon E g 8 30...

Page 17: ...hat will only work during pre set times and days of the week Temporary Prox cards which auto expire in a pre se time Check stored Prox cards Intercom will reply with SMS message Temporary Code Stores...

Page 18: ...during pre set days and times of the week Relay 1 only Enter start time in 24hr format military style with no colon E g 8 30am 0830 Enter end time in 24hr format military style with no colon E g 1 30...

Page 19: ...D to be deleted Deleting ALL cards 9999 64 Enter known card ID 10 digits xxxxxxxx Delete all stored cards and start again Auto Expiring Temp Cards Store up to 30 cards which auto expire within a certa...

Page 20: ...losing gates use latching and unlatching commands to control open times 1234 1 day day day time USER passcode Command 1 trigger relay 1 2 latch relay 1 3 unlatch relay 1 4 trigger relay 2 5 latch rela...

Page 21: ...button press outside of these times will be ignored by the intercom Quick enable disable button Set start and end time for button active times 24hr format no colon E g 8 30am 0830 Set the days in whi...

Page 22: ...osition 1 4 Programming codes There are 2 main SMS programming pass codes on the intercom One for the installer default 9999 and the other for the user homeowner default 1234 It is advised to change t...

Page 23: ...mber 9999 46XX X dialling time for second number 9999 47XX X dialling time for third number 9999 53XX X talking time in seconds 9999 max Volumes Adjust microphone and speaker volumes 1 9 default 5 If...

Page 24: ...nt 22 Open Relay1 on Relay2 off open refers to state of the status input connection in the intercom Relay 1 and 2 will show ON if latched 1234 26 NORM xxxx PLAN xxxxx TEMP xxxxx 1234 25 NORM xxxx PLAN...

Page 25: ...out numbers 9999 1XY Store dialling out numbers X button number 1 9 0 for button 10 Y number dialled 1 4 phone number N A 9999 1XY Delete a dial out number X button number Y number position 1 4 N A Vo...

Page 26: ...99 58 Choose between making a scheduled call or scheduled SMS 1 SMS 2 call 1 9999 77 Delete the stored service number N A Caller ID features 9999 72number Store caller ID number Max 14 digits Only las...

Page 27: ...ct 9999 87 number of days between SMS calibration SMS should be sent 0 no message sending N A Do Not Disturb push button de activated during set times 1234 21 ON ON activated OFF de activated OFF 9999...

Page 28: ...time as per programming instructions Q The caller ID part does not work A Be sure to program the caller ID part under 72 feature If your number is a private or number withheld then it will not work E...

Page 29: ...power supply directly to the unit Q The system was operating the gates fine but now it will not trigger the gates Frequently this is cause by the user accidentally latching the relay This latches the...

Page 30: ...product s or has been subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under conditions m...

Page 31: ...erference and 2 this device must accept any interference received including interference that may cause undesired operation Output power listed is ERP below 1GHz for Part 22 and EIRP above 1GHz for Pa...

Page 32: ...32 Note For legal reasons telephone technical support is for registered and qualified product dealers only Home owners and end users should contact their local dealer for product technical support...

Reviews: