5.3 CONNECTIONS
CONTROL DEVICES
RP/DEC
MO
TOR
LAM
P
M
AINS
2EASY
OPEN SX OPEN DX
LIMIT SW
F
-
+
OPEN B
OPEN A
SAFE CL
CL -H
OP-H
SAFE OP
STOP
GND
GND
OUT 1
OUT 2
TEST OUT
+24V
N
L1
U
V
W
L2
L3
M
3
LAMP
N
GND
+24V
FCC
FC
A
230V~
60W max
1500 W max
1
2
3
4
5
6
7
8
9
10
11
12
13
400V~ 3PH + N
INPUT
CN9
Connect the devices to terminal board CN9.
i
Multiple NO contacts on same input must be con-
nected in parallel.
Multiple NC contacts on same input must be con-
nected in series.
1 GND
Common contacts
2 STOP
(Stop command)
NC contact, connect a push-button or another type of
pulse generator which, by opening a contact, causes
the automation to stop.
i
If the input is not used, bridge it with GND
3 CL - H
(PRIORITY close command)
NO contact, connect a push-button that, as long as it
keeps a contact closed, commands the closing of the
gate in hold-to-run mode without any monitoring of
safety devices.
!
Activation must be intentional and the
gate must be visible
4 OP - H
(PRIORITY open command)
NO contact, connect a push-button that, as long as it
keeps a contact closed, commands the opening of the
gate in hold-to-run mode without any monitoring of
safety devices.
!
Activation must be intentional and the
gate must be visible
5 SAFE CL
(Safety in closing active)
Connect a sensitive edge or another device that, when
activated during closing, causes the gate to reverse
partially or completely.
This input can be configured by setting programming
function
Sc
to connect:
- sensitive edges with NC contact
- resistive sensitive edges 8.2 kΩ -default-
- photocells
Reverse after a sensitive edge has been activated can
be configured by setting programming function
iP
:
- partial reverse of 3 s (
iP
=
Y
)
- complete reverse (
iP
=
no
)
6 SAFE OP
(Safety in opening active)
Connect a sensitive edge or another device that, when
activated during opening, causes the gate to reverse
partially or completely.
This input can be configured by setting programming
function
So
to connect:
- sensitive edges with NC contact
- resistive sensitive edges 8.2 kΩ -default-
- photocells
Reverse after a sensitive edge has been activated can
be configured by setting programming function
iP
:
- partial reverse of 3 s (
iP
=
Y
)
- complete reverse (
iP
=
no
)
7 OPEN B
(PARTIAL motion command)
NO contact, connect a push-button or another type of
pulse generator which, by closing a contact, commands
the partial opening of the gate.
The partial opening width is set in programming func-
tion
PO
(from 1 to 20 s).
The effect that subsequent pulses have depends on
the operating logic set in programming function
Lo
.
8 OPEN A
(TOTAL motion command)
NO contact, connect a push-button or another type of
pulse generator which, by closing a contact, commands
the total opening of the gate.
The effect that subsequent pulses have depends on
the operating logic set in programming function
Lo
.
i
By default, the SAFE CL and SAFE OP inputs are con-
figured to connect resistive type sensitive edges. If
one or both are not used, set function
So
and/or
Sc
=
nc
and bridge with the common contacts (GND
terminal), otherwise they would be active.