E024S
8
732642 - Rev. F
6
START-UP
6.1
LEDS CHECK
Check the status of the inputs, from the LEDs on the board (Tab.1).
Tab. 1: input LED status
(the condition of closed automation in standby is provided in
bold)
LED STATUSES
LED
ACTIVE CONTROL
NOT ACTIVE CONTROL
STOP
Off
On
OPEN A
On
Off
OPEN B
On
Off
BUS
See paragraph 7.2
6.2
PROGRAMMING THE DIP-SWITCHES
The settings of the DS1 dip-switch for programming the force
and the type of motor are shown in the following table.
Tab. 2 - DS programming
(default settings in bold)
Before performing the Setup, select the op-
erator connected to the E024S unit with the
DS1(DS3-DS4) DIP switches.
6.3.1 AUTOMATIC SETUP
To enter the Automatic setup, press the SETUP push-button until
the two LD4 and LD5 LEDs are permanently lit. Then release
the SETUP push-button.
During the Setup phase both LEDs flash.
The leaves start to open one at a time, from any position,
till they detect the opening limit stop. Next, the leaves start
to close, one at a time, till they detect the closing limit stop.
Then, the leaves start again to move automatically one at a
time from the closed position.
1. When the leaves detect the opening limit stop, they stop in
the open position and the set-up is completed.
If the SETUP procedure is performed correctly , the LD4 and
LD5 LEDs turn off at the end. Otherwise the procedure ends
by asking a new SETUP with flashing LEDs.
With the AUTOMATIC SETUP, the deceleration
spaces, the leaf closing delays and the pause
time (30 s, with logic A) are automatically
preset during setup.
6.3.2 MANUAL SETUP
To enter the Manual setup, press the SETUP push-button until
both LD4 , press the SETUP push-button until the two LD4 and LD5
LEDs are permanently lit. Keep it pressed until the automated
system starts moving automatically.
During the Setup phase both LEDs flash.
The leaves start to open one at a time, from any position till they
detect the opening limit stop. Next the leaves start to close one
at a time till they detect the closing limit stop.
Then the leaves start again to move automatically one at a
time from the closed position.
1. Open impulse --->leaf 1 decelerated opening and start of
the search for leaf 1 opening limit stop
-
if the limit stop is detected, it is set as stop point for leaf 1
and leaf 2 starts to open.
(*) if an open command is detected, it is set as opening
stop point for leaf 1 and leaf 2 starts to open.
2. Open impulse ---> leaf 2 decelerated opening and start
of the search for leaf 2 opening limit stop.
-
if the limit stop is detected, it is set as opening stop point
for leaf 2.
(*)
if an open command is detected, it is set as opening stop
point for leaf 2.
DS4
DS3 DS2 DS1
Description
OFF
OFF
MOTOR 391
ON
OFF
MOTOR 418
OFF
ON
MOTOR 412-413-415-390-770
ON
ON
HYDRAULIC MOTOR (*)
S450H/S700H/S800H/S800H ENC
OFF OFF
LOW FORCE
ON OFF
MEDIUM - LOW FORCE
OFF ON
MEDIUM - HIGH FORCE
ON
ON
HIGH FORCE
6.3
TIME LEARNING – SETUP
Before any manoeuvre is executed, a SETUP cycle
must first be run.
If the motor type is changed with the DS3 and
DS4 dip-switches after the SETUP, a new SETUP is
requested with flashing LD4 and LD5 LEDs.
If, after the start of the SETUP procedure, the
leaves close instead of open, reverse the motor
power cables
(*) with the DS3-DS4 selection on ON the opera-
tor connected to the encoder is automatically
recognized during the set-up phase
Important:
The dip-switch arrangement on the E024S board
for 391 is overturned.
When the board is powered up and a SETUP cycle has
never been executed, LEDs LD4 and LD5 begin to flash
slowly to signal that a SETUP cycle must be executed.
There are two possible types of SETUP:
- AUTOMATIC SETUP
- MANUAL SETUP
(*) During SETUP, to set the stop point, the OPEN
command must ONLY be used with SAFECODER
ENGLISH
Summary of Contents for E024S