E024S
16
732642 - Rev. F
(1) if the cycle began with OPEN-B (released leaf), both leaves are activated at opening
LOGIC “EP”
PULSES
AUTOMATED SYSTEM STATUS
OPEN A
OPEN B
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens the leaves opens released
leaf
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING
stops operation
(1)
stops operation
stops operation
immediately
reverses at clo
-
sure
no effect
stops and opens at
release
(OPEN stops -
saves CLOSE)
OPEN
recloses leaves
immediately (1)
recloses leaves
immediately
no effect
(OPEN/CLOSE
disabled)
no effect
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE disabled)
CLOSING
stops operation
stops operation
stops operation
no effect
reverses at opening
stops and opens at
release
(OPEN stops -
saves CLOSE)
BLOCKED
restarts moving in
opposite direction.
Always closes after
STOP
restarts moving in
opposite direction.
Always closes after
STOP
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN stops -
saves CLOSE)
LOGIC “E”
PULSES
AUTOMATED SYSTEM STATUS
OPEN A
OPEN B
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens the leaves opens released
leaf
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING
stops operation
(1)
stops operation
stops operation
immediately
reverses at
closure
no effect
stops and opens at release
(OPEN stops - saves CLOSE)
OPEN
recloses leaves
immediately (1)
recloses leaves
immediately
no effect
(OPEN/CLOSE
disabled)
no effect
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE disa
-
bled)
CLOSING
reopens leaves
immediately
reopens leaves
immediately
stops operation
no effect
reverses at opening
stops and opens at release
(OPEN stops - saves CLOSE)
BLOCKED
closes leaves
closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN stops -
saves CLOSE)
(1) if the cycle began with OPEN-B (released leaf), both leaves are activated at opening
(1) if the cycle began with OPEN-B (released leaf), both leaves are activated at opening
LOGIC “AP”
PULSES
AUTOMATED SYSTEM STATUS
OPEN A
OPEN B
STOP
FSW OP
FSW CL
FSW CL/OP
CLOSED
opens and closes
after pause time
opens released
leaf and closes
after pause time
no effect
(OPEN disabled)
no effect
(OPEN disabled)
no effect
no effect
(OPEN disabled)
OPENING
stops operation
(1)
stops operation
stops operation
reverses at
closure (saves
OPEN)
no effect
stops and opens at
release
(OPEN stops -
saves CLOSE)
OPEN IN PAUSE
stops operation
(1)
stops operation
stops operation
no effect
recharges
pause time
(CLOSE disabled)
recharges
pause time
(CLOSE disabled)
CLOSING
reopens leaves
immediately
reopens leaves
immediately
stops operation
no effect
reverses at opening
stops and opens at
release
(OPEN stops -
saves CLOSE)
BLOCKED
closes leaves
closes leaves
no effect
(OPEN/CLOSE
disabled)
no effect
(OPEN disabled)
no effect
(CLOSE disabled)
no effect
(OPEN/CLOSE disa
-
bled)
ENGLISH
Summary of Contents for E024S