background image

10

Fig. 10

Fig. 9

• Turn the release key anti-clockwise for 2-3 turns.

• Remove the fitting from the operator and fit it on the leaf. The

fitting can be either welded directly or screwed on, using the
threaded inserts (Fig. 9).

4.3.7 Installing the front fitting

Fasten the operator to the front fitting as shown in Fig. 10 and turn
the release key clockwise to the closing stop position.

Ü

The operator is non-reversing,  so do not, on any account,
try to move the leaves by hand.

4.3.8 Installing the operator-front fitting

5.

MANUAL OPERATION

If the gate has to be moved manually due to a malfunction of
the automated system, use the release device as follows:

• Fit the supplied Allen wrench in the front part of the operator

and turn it anti-clockwise for 5-6 turns (Fig. 11 Ref. 

).

• Lift the operator by its front end, detaching it from the fitting

(Fig. 11 Ref.

) and remove the release key.

6.

RESTORING NORMAL OPERATION MODE

Procedure to relock the gate:

• Re-position the operator on the front fitting (Fig. 10);

• Fit and turn the release key clockwise until the operator

reaches the closing stop position.

• remove the release key.

Fig.  11

a

b

a

b