background image

7

These instructions apply to the following model:

FAAC DOMOLINK

The DOMOLINK automated system can automate residential swing gates with leaves of up to 1.8 m in length with 120° max.
opening.

It consists of non-reversing electro-mechanical articulated operators, powered by 12 Vdc, and each operator is coupled to a
control unit. The non-reversing system guarantees the gate will automatically lock when the motor is not operating. A release
system enables the gate to be moved by hand in case of malfunction.

The DOMOLINK automated system was designed and built for controlling vehicle access. Do not use for any other purpose.

DOMOLINK automated system

MODEL

DOMOLINK battery

DOMOLINK transformer

Power supply

12Vdc

Rated absorbed power (W)

48

Max torque (Nm)

70

Max load-free angular speed (°/sec)

23 (0.4 rad/sec)

Use frequency (cycles/hour)

5

(1)

15

(2)

Consecutive cycles

~15

(1)

30

(2)

Recovery time

~10' for each completed cycle

(1)

2' for each completed cycle

(2)

Type of reduction gear

epicycloid

Operating ambient temperature (°C)

-20 ÷ +55

Operator weight (Kg)

2.8

Protection class

IP 44

Leaf max length (m)

1.80

Leaf max weight (kg)

250

Operator overall dimensions LxHxD (mm)

see fig.2

Length of operator power cable (m)

0.7 

(CANNOT BE MODIFIED)

Tab. 1 

- Technical specifications of DOMOLINK operator

3.

TECHNICAL SPECIFICATIONS

(1)

The 5 cycles/hour are just a reference value for maintaining full efficiency of batteries. 15 consecutive cycles can be averagely
performed with charged battery. The recovery time (battery recharge) is approx. 10' each cycle performed. The consecutive cycles
could be reduced by over 50% at low temperatures (< 0°C).

Fig. 1

1.

DESCRIPTION

2.

DIMENSIONS

a

DOMOLINK operator

b

Rear fitting

c

Front fitting

d

Release

Fig. 2

• 

Dimensions in mm

DOMOLINK

OPERATOR

(2)

The 15 cycles/hour are just a reference value for maintaining full efficiency of motorisation. 30 consecutive cycles can be performed
with software thermal protection. Recovery time is 2' each cycle performed.