•  Left or right encoder position

In order for EP104 to determine that the motor is moving in the correct direction, the settings in L-channels must be made 

correctly. To find out which drive unit to be left or right, see picture below. Top mounted drive unit with one motor should 

be set as right.

L110=1, Motor 1 Left position

L120=2; Motor 2 Right position

L113, Closed position

L123, Closed position

L112, Open position

L122, Open position

L121, Position readout

L1

11, Position readout

•  Connections

The Encoder terminals work as shown in the table below.

No

Function

1

Power supply 12-24 VDC

2

GND

3

Analog output to EP104

4-9 Free connection points, Max 24 VDC, the terminals have no function for the encoder.

•  Light indication

To the left of terminal number 1 there is a LED indicator that lights green when the card is powered by 12-24 VDC.

Description of the magnet

The magnet that is mounted on the shaft has to be adjusted due to top mounted or side mounted drive unit. Before the magnet 

adapter could be rotated the screw at the side of the adapter must be lossed. On a side mounted drive unit the arrow on the 

magnet should point att the drive arm. On a top mounted drive unit the arrow should point away from the drive arm.