background image

2

INSTRUCTION MANUAL DAAB ENCODER DB405

2

Technical data

Temperature range

-40 to 50 °C

Light indication

The power supply voltage is indicated by a green LED

Degree of protection

The PCB is designed for internal installation in a DAAB driver unit

Cable length

Maximum 50 meters at cable area 0.75 mm

(

 

1 mm).

Note that separate conductors for connecting the DB405 should be used.

If you are to order an encoder as a spare part for mechanical limit switches, please contact FAAC Nordic AB.

Installation of DB405

The encoder is a circuit board that together with a magnet replaces mechanical limit switches. The encoder transforms the 

magnet’s position to a voltage which then EP104 converts to a number of degrees. In EP104, you set the limits for open 

and closed positions in the L-channels. The encoder is working with drive units MK, MA, MK2, MA2 and MT. For more 

information see Instruction Manual for Control Unit EP104.

•  Connecting an encoder (electronic limit switch)

The encoder is connected to EP104 as shown below.

DB405

Motor 1

DB405

Motor 2

Control unit

EP104 with software version

4.04 4.05 or 4.06

14

17

1

2

3

1

2

3

34

L.O1

L.O2

GND

+12-

24V GND

GND

L.OUT

L.OUT

+12V

37

+12-

24V

DB405

Motor 1

DB405

Motor 2

Control unit

EP104 with software version

4.07 or higher

14

17

1

2

3

1

2

3

34

L.O1

L.O2

GND

GND

GND

L.OUT

L.OUT

+24V

13

+24V

16

+12-

24V

+12-

24V

Reviews: