B614
48
732998 - Rev.A_DRAFT
Tr
ansla
tion of the original instruc
tions
ENGLISH
12
Addressing control devices
0 0 0 0
Open A_1
0 0 0 1
Open A_2
0 0 1 0
Open A_3
0 0 1 1
Open A_4
0 1 0 0
Open A_5
0 1 0 1
Stop
0 1 1 0
Stop NC_1
0 1 1 1
Stop NC_2
1 0 0 0
Close
1 0 0 1
Open B_1
1 0 1 0
Open B_2
1 0 1 1
Open B_3
1 1 0 0
Open B_4
1 1 0 1
Open B_5
1 1 1 0
/
1 1 1 1
/
0 0 0 0
Open A_1
Open B_1
0 0 0 1
Open A_1
Open B_2
0 0 1 0
Open A_1
Stop
0 0 1 1
Open A_1
Close
0 1 0 0
Open A_2
Open B_1
0 1 0 1
Open A_2
Open B_2
0 1 1 0
Open A_2
Stop
0 1 1 1
Open A_2
Close
1 0 0 0
Open A_3
Open B_3
1 0 0 1
Open A_3
Open B_4
1 0 1 0
Open A_3
StopNC_1
1 0 1 1
Open A_3
Close
1 1 0 0
Open A_4
Open B_3
1 1 0 1
Open A_4
Open B_4
1 1 1 0
Open A_4
StopNC_2
1 1 1 1
Open A_4
Close
2. Register the BUS 2easy control devices (
bu
Basic
Programming).
3. Check the status of LEDs DL3 and DL7 (
).
4. Check that the devices are working properly. Use
the controls to make the barrier move. Check the
LEDs on the devices, the status of the bus on the
display and make sure that the automation system
operates according to the type of device installed.
BUS 2EASY DEVICE REGISTRATION
Registration is required:
-
When the automation system is first started or after
the board has been replaced.
-
Following any changes (addition, replacement or
removal) to the BUS 2easy devices.
ON
1 2 3 4 5
1 command
DIP switch 5 =
0 (OFF)
ON
1 2 3 4 5
2 commands
DIP switch 5 =
1 (ON)
Registration procedure:
1. Select
parameter
bu
in basic programming. When
F
is released, the display shows the status of the
BUS 2easy devices
).
2. Press and hold the
+
and
-
buttons simultaneously
for at least 5 seconds until
Y
appears (the display
flashes during this time). Registration has been
completed.
3. Release
the
+
and
-
buttons. The display indicates
the status of the BUS 2easy devices.
4. Check the status of the LEDs on the board:
LED DL7 (Red) - BUS 2easy devices
At least one device is engaged/active
No device is engaged/active
LED DL3 (Green) - BUS 2easy line
Line monitoring. LED always on (off with board in Sleep
mode)
Line short-circuited
Device error: check the ERROR LED
Registered device verification procedure:
1. Select
parameter
bu
in basic programming. After
registering one or more devices,
bu
displays seg-
ment 13 on.
2. Press and hold the
+
button and keep it pressed;
the segments relative to the registered devices
will come on. Each segment of the display cor-
responds to a type of device:
1
Open A control device
2
Open B control device
3
Closing photocells
4
Photocells for Open impulse
5
Not used
6
Close control device
7
Not used
8
Stop control device
9
Closing edge
10
Not used
11
Not used
12
Opening edge
13
BUS 2easy status
14
Not used