10
3.6.
SIGNALLING LEDs
6 LEDs are fitted on the card, indicating status of terminal board
inputs:
L
ED
LIGHTED
= contact closed
L
ED
OFF
= contact open
4.
PROGRAMMING
To program operation of automation, use the microswitches as
shown below.
1
2
3
4
5 6 7
Operation of warning light
Gate status
SW6 Closed
Opening/Open
Closing
ON
OFF
Light
Flashing
Light
Off
Steady light
Pre-flashing (2)SW7
Yes
ON
No
OFF
Logic
SW1
SW2
SW3
E1
ON
ON
ON
B
OFF
ON
ON
S2
ON
OFF
ON
E2
OFF
OFF
ON
A1
ON
ON
OFF
C
OFF
ON
OFF
S1
ON
OFF
OFF
A2
OFF
OFF
OFF
Pause time (sec) (1)
Logic
A1-A2-S2
S1
SW4
SW5
5
15
ON
ON
10
30
OFF
ON
30
60
ON
OFF
120
180
OFF
OFF
ON
OFF
(1) Pause times include pre-flashing if any
(2) Pre-flashing begins 5” before every movement.
!
You must press the RESET push-button after every program-
ming job.
4.1. FUNCTION LOGICS
The following are available:
A1/A2 = “Automatic”
S1/S2 = “Safety”
E1/E2/B = “Semi-automatic”
C = “Dead man”
Operation of automation in the different logics is indicated in
Tables 3 - 4 - 5 - 6 - 7 - 8 - 9 - 10.
4.2. PAUSE TIME
Pause time is waiting time in open position before re-closing
when an automatic logic was selected.
Pause times include pre-flashing if any
4.3. OPERATION OF WARNING LIGHT
Used to change the appearance of the warning light at closing
by making it flash.
4.4. PRE-FLASHING
Flashlight pre-flashing time of 5 sec before any movement can
be selected. This warns anyone near the gate that it is about to
move.
5. FAULT CONDITIONS
The following conditions cause certain effects to normal opera-
tion of automation:
햲
microprocessor error
햳
safety electronic timing tripped (operation is interrupted if
continuous work time exceeds 255 sec. ).
햴
limit sensors disconnected (or both engaged)
• Conditions
햲
and
햳
cause automation to stop and nothing
more.
• Condition
햴
causes an alarm situation disabling any activ-
ity:
• Normal operation can be restored only after eliminating the
alarm cause and pressing the RESET push-button (or turning
off power supply momentarily).
• To have this condition signalled, the warning light must be
connected: the alarm is signalled by very rapidly flashing light
(0.25 sec).
NB.:
The status of the LEDs while the gate is closed at rest are
shown in bold.
D
E
L
D
E
T
H
G
I
L
F
F
O
A
N
E
P
O
e
v
i
t
c
a
d
n
a
m
m
o
C
e
v
i
t
c
a
n
i
d
n
a
m
m
o
C
B
N
E
P
O
e
v
i
t
c
a
d
n
a
m
m
o
C
e
v
i
t
c
a
n
i
d
n
a
m
m
o
C
P
O
T
S
e
v
i
t
c
a
n
i
d
n
a
m
m
o
C
e
v
i
t
c
a
d
n
a
m
m
o
C
W
S
F
g
n
i
t
a
r
e
p
o
t
o
n
s
e
c
i
v
e
d
y
t
e
f
a
S
g
n
i
t
a
r
e
p
o
s
e
c
i
v
e
d
y
t
e
f
a
S
C
C
F
e
e
r
f
r
o
s
n
e
s
t
i
m
il
g
n
i
s
o
l
C
d
e
g
a
g
n
e
r
o
s
n
e
s
t
i
m
i
l
g
n
i
s
o
l
C
A
C
F
e
e
r
f
r
o
s
n
e
s
t
i
m
i
l
g
n
i
n
e
p
O
d
e
g
a
g
n
e
r
o
s
n
e
s
t
i
m
il
g
n
i
n
e
p
O
Tab. 2 - STATUS OF LEDS