16
1
Brake adjustment: Turn the potentiometer
counterclock-wise to decrease the braking force and
clockwise to increase the braking force.
2
Reset
3
Fuse F2, 1.6 A, for the power supply to accessories
4
Fuse F3, 250 mA, for the transformer
5
Fuse F1, 5 A, for the electric motor
6
Terminal block J7 for connecting a flashing warning
light (maximum load of 60 W)
7
Terminal block J8 for connecting the power supply to
the 844 operator
8
Terminal block J6 where the 35
µ
F capacitor is
connected
9
Terminal block J5 where the motor is connected
10
Terminal block J4 for right-closing limit switch
connection
11
Terminal block J3 for left-closing limit switch
connection
12
Jumper: do NOT cut or remove
13
Terminal block J2 for low-voltage accessories
14
Light-emitting diodes (LEDs) for signalling gate status
15
Connector for MD01 board
16
DIP switch assembly
Figure 16. The 844 MPS Control Panel
FAAC
MINILAMP
POWER
SUPPLY
CO
MMO
N
CO
MMO
N
CO
MMO
N
OPEN
STOP
FSW
COMMON
COMMON
COMMON
Figure 17. The 844 MPS terminal strip. See Figure 13 for the connection of the limit switch ribbon
cable appropriate to your gate design.