6
FAAC Model 770 Underground Swing Gate Operator
The FAAC 770 is an electomechanical operator for swing gates. It
is designed for underground installation and therefore does not alter
the appearance of the leaf.
The supplied foundation box allows you to setup the gate before
actually installing the operator.
The 770 electromechanical operator is irreversible, so it ensures a
mechanical stop and eliminates the need to install an electric lock.
1 Foundation Box
2 Bores for Fastening Box Cover (3)
3 770 Operator
4 Support Bracket for Gate
5 Locking Bracket
6 Release Device with Key
7 Operator Ground Connection
8 Crank and Connecting Rod Assembly
9 Pinion
10 Bore for Power Supply Cable Pipe
11 Bore for Drain Pipe
12 Fastening Screws for Operator (4)
13 Lubrication Bore
3.1. PRELIMINARY CHECKS
To ensure trouble-free operation, ensure that the gate (whether exist-
ing or yet to be installed) adheres to the following specifications:
•
Max. single leaf weight: 1100 lbs.
•
Max. single leaf length: 98.5 inches.
•
Strong and rigid leaf frame.
•
Smooth gate movement, with no stiff points.
•
Proper minimum clearance between bottom edge of gate and
ground. See Fig. 6a (where ‘
s
’ = thickness of guide bracket)
•
Mechanical travel stops.
The condition of the gate directly affects the reliability and safety of
the automation system. If any welding has to be done on the gate,
complete it before installing the automation system.
Fig. 1
2. STANDARD INSTALLATION LAYOUT
Fig. 2
3.2 INSTALLING THE LEAF SUPPORTING
FOUNDATION BOX (Fig. 3)
a) For Existing Gates with Fixed Hinges:
•
Remove the gate.
•
Remove the bottom hinge.
If the gate cannot be removed, place blocks under its bottom edge to
support it.
12⅛
17
6⅛
8½
Fig. 3
1
2
3 4
5
8
6
7
9
10
11
12
13
770 Operators (require 2 junction boxes)
Photocells
Control Unit
T10 Pushbutton
Receiver
Flashing Light
1) Use suitable rigid/flexible pipes for laying power cables.
2) Always keep low voltage accessory cables separated
from 230V~ power cables. To avoid interference, use
separate sheaths.
Table 1b: Electric Motor Specifications
1. DESCRIPTION & CHARACTERISTICS
3. INSTALLING THE SYSTEM
Operator
770
Reduction Ratio
1400:1
Motor Winding Thermal Cutout (°F)
284
Temperature Range
-4°F to +131°F
Maximum Torque (Nm)
300
Angular speed (°/sec)
6
Opening Time (secs)
1 (90°), 8 (110° and 180°), 10.5
(140°)
Operator Weight (lbs)
26.5 lbs (carrying box: 31 lbs)
Type and Frequency of Use at 68°F
100%
Indicative Hour Cycles at 68°F
100 (100° and 180°) , 170 (140°)
Max. leaf opening angle
110° (140° and 180° with kit)
Max. leaf weight (lbs)
1100
Power cable length (inches)
78.75
Housing protection
IP 67
Operator dimensions (inches)
14.25 x 6 x 5.5
Max. leaf length (inches)
138 (110°), 118 (180°), 98.5 (140°)
Table 1a: Operator Specifications
Power Supply
24 VDC
Absorbed power (W)
70
Current Drawn (A)
3
Electric Motor (rpm)
1400
* Measurements in Inches
FAAC Model 770 Underground Swing Gate Operator