background image

6

FAAC Model 770 Underground Swing Gate Operator

The FAAC 770  is an electomechanical operator for swing gates. It 

is designed for underground installation and therefore does not alter 

the appearance of the leaf.
The supplied foundation box allows you to setup the gate before  

actually installing the operator.
The 770 electromechanical operator is irreversible, so it ensures a 

mechanical stop and eliminates the need to install an electric lock. 

1  Foundation Box
2  Bores for Fastening Box Cover (3)
3  770 Operator
4  Support Bracket for Gate
5  Locking Bracket
6  Release Device with Key
7 Operator Ground Connection

8  Crank and Connecting Rod Assembly
9  Pinion
10  Bore for Power Supply Cable Pipe
11  Bore for Drain Pipe
12  Fastening Screws for Operator (4)
13  Lubrication Bore

3.1.  PRELIMINARY CHECKS

To ensure trouble-free operation, ensure that the gate (whether exist-

ing or yet to be installed) adheres to the following specifications:

• 

Max. single leaf weight: 1100 lbs.

• 

 Max. single leaf length: 98.5 inches.

• 

 Strong and rigid leaf frame.

• 

Smooth gate movement, with no stiff points.

• 

Proper minimum clearance between bottom edge of gate and 

ground. See Fig. 6a (where ‘

s

’ = thickness of guide bracket)

• 

Mechanical travel stops.

The condition of the gate directly affects the reliability and safety of 

the automation system. If any welding has to be done on the gate, 

complete it before installing the automation system.

Fig. 1

2.  STANDARD INSTALLATION LAYOUT

Fig. 2

3.2  INSTALLING THE LEAF SUPPORTING 

FOUNDATION BOX (Fig. 3)

a)  For Existing Gates with Fixed Hinges:

• 

 Remove the gate.

• 

 Remove the bottom hinge.

If the gate cannot be removed, place blocks under its bottom edge to 
support it.

12⅛

17

6⅛

Fig. 3

1

2

3 4

5

8

6

7

9

10

11

12

13

 

770 Operators (require 2 junction boxes)

 

Photocells

 

Control Unit

 

T10 Pushbutton

 

 

Receiver

 

Flashing Light

1)  Use suitable rigid/flexible pipes for laying power cables.

2)  Always keep low voltage accessory cables separated 

from 230V~ power cables. To avoid interference, use 

separate sheaths.

Table 1b: Electric Motor Specifications

1.  DESCRIPTION & CHARACTERISTICS

3.  INSTALLING THE SYSTEM

Operator

770

Reduction Ratio

1400:1

Motor Winding Thermal Cutout (°F)

284

Temperature Range

-4°F to +131°F

Maximum Torque (Nm)

300

Angular speed (°/sec)

6

Opening Time (secs)

1 (90°), 8 (110° and 180°), 10.5 

(140°)

Operator Weight (lbs)

26.5 lbs (carrying box: 31 lbs)

Type and Frequency of Use at 68°F

100%

Indicative Hour Cycles at 68°F

100 (100° and 180°) , 170 (140°)

Max. leaf opening angle

110° (140° and 180° with kit)

Max. leaf weight (lbs)

1100

Power cable length (inches)

78.75

Housing protection 

IP 67

Operator dimensions (inches)

14.25 x 6 x 5.5

Max. leaf length (inches)

138 (110°), 118 (180°), 98.5 (140°)

Table 1a: Operator Specifications

Power Supply

24 VDC

Absorbed power (W)

70

Current Drawn (A)

3

Electric Motor (rpm)

1400

* Measurements in Inches

FAAC Model 770 Underground Swing Gate Operator

Summary of Contents for 770 COMPACT

Page 1: ...onal Inc Headquarter East Coast Operations 5151 Sunbeam Road Suites 9 11 Jacksonville FL 32257 Tel 866 925 3222 www faacusa com FAAC International Inc West Coast Operations 357 South Acacia Avenue Uni...

Page 2: ...tion Instructions 3 General Safety Precautions 4 UL325 Gate Operator Classifications 5 Installing the Warning Signs 5 1 DESCRIPTION CHARACTERISTICS 6 2 STANDARD INSTALLATION LAYOUT 6 3 INSTALLING THE...

Page 3: ...r Reset buttons must be located within line of sight of the gate Activation of the reset control shall not cause the operator to start 7 All warning signs and placards must be installed and easily see...

Page 4: ...easonable use If a gate system component malfunctions disconnect the main power before attempting to repair it Do not impede the movement of the gate you may injure yourself or damage the gate system...

Page 5: ...dings such as factories loading docks or other locations not intended to service the general public RESTRICTED ACCESS VEHICULAR GATE OPERATOR CLASS IV A vehicular gate operator system intended for use...

Page 6: ...lding has to be done on the gate complete it before installing the automation system Fig 1 2 STANDARD INSTALLATION LAYOUT Fig 2 3 2 INSTALLING THE LEAF SUPPORTING FOUNDATION BOX Fig 3 a For Existing G...

Page 7: ...ions provided in Figs 6a and 6b The center of the pivot on the foundation box must be perfectly aligned with the leaf s axis of swing Figs 6a and 6b 3 Lay down a 1 5 inch diameter PVC tube through whi...

Page 8: ...the driving levers supplied as shown in Fig 13 Note grease the operator pinion and the fixing pivots of the two levers 4 Install the second operator if required by repeating the opera tions described...

Page 9: ...til the lock is engaged in the locking bracket Fig 16 Ref 3 4 Close the lid on the lock 7 RETURNING TO NORMAL OPERATION 8 MAINTENANCE Fig 16 9 REPAIRS 1 Program the electronic control unit according t...

Page 10: ...70 1 1 Y 770 24V MOTOR 002 716078 1 1 Y 770 GEAR BOX 004 727158 1 1 Y 770 GEAR BOX COVER 007 718076 1 1 Y SW G O THIRD INTERNAL SHAFT GROUP 008 719165 1 1 Y SW G O 770 INTERNAL SLOW SHAFT 010 390451 0...

Page 11: ...of the product s or has been subject to misuse negligence or accident or has not been operated in accordance with FAAC International Inc s or FAAC S p A s instructions or has been operated under cond...

Reviews: